The design of center tap Rogowski coil to detect partial discharge in low voltage and medium voltage power cable

TK7878.4.M83 2018

Saved in:
Bibliographic Details
Main Author: Muhammad Aizatuddin Aniq Kamisan
Format: text::Final Year Project
Language:en
Published: 2024
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1840210130463883264
author Muhammad Aizatuddin Aniq Kamisan
author_facet Muhammad Aizatuddin Aniq Kamisan
author_sort Muhammad Aizatuddin Aniq Kamisan
building UNITEN Library
collection Institutional Repository
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
continent Asia
country Malaysia
description TK7878.4.M83 2018
format Resource Types::text::Final Year Project
id my.uniten.dspace-31908
institution Universiti Tenaga Nasional
language en
publishDate 2024
record_format dspace
spelling my.uniten.dspace-319082025-08-11T10:05:59Z The design of center tap Rogowski coil to detect partial discharge in low voltage and medium voltage power cable Muhammad Aizatuddin Aniq Kamisan Electronic instruments Electric rails TK7878.4.M83 2018 Rogowski coil has been applied widely in the field of partial discharge measurement. Limited capabilities in Rogowski coil require a new design to increase sensitivities for it in a very low-level partial discharge. High-frequency current transformer is expensive to design and not manufactured locally. There is a need for a universal, low-cost alternative that is suitable to the needs of the local power industry. In the present work, center tap current transformer characteristics are studied. This thesis mainly introduces center tap Rogowski coil applied in partial discharge collection, analyzes and compares with a commercial high-frequency current transformer. The experiment is done by applying sinusoidal input, noise input and pulse input measured by both Rogowski coil and high-frequency current transformer. Cost evaluation is also calculated to show the performance of the Rogowski coil compared to the high-frequency current transformer. The experimental result indicates that the Rogowski coil proves a better alternative compared to a high-frequency current transformer. 2024-04-23T00:58:01Z 2024-04-23T00:58:01Z 2018 Resource Types::text::Final Year Project https://irepository.uniten.edu.my/handle/123456789/31908 en application/pdf
spellingShingle Electronic instruments
Electric rails
Muhammad Aizatuddin Aniq Kamisan
The design of center tap Rogowski coil to detect partial discharge in low voltage and medium voltage power cable
title The design of center tap Rogowski coil to detect partial discharge in low voltage and medium voltage power cable
title_full The design of center tap Rogowski coil to detect partial discharge in low voltage and medium voltage power cable
title_fullStr The design of center tap Rogowski coil to detect partial discharge in low voltage and medium voltage power cable
title_full_unstemmed The design of center tap Rogowski coil to detect partial discharge in low voltage and medium voltage power cable
title_short The design of center tap Rogowski coil to detect partial discharge in low voltage and medium voltage power cable
title_sort design of center tap rogowski coil to detect partial discharge in low voltage and medium voltage power cable
topic Electronic instruments
Electric rails
url_provider http://dspace.uniten.edu.my/