Fault analysis of HVDC converter based on alternate arm converter topology

Recent advancement of High Voltage Direct-Current (HVDC) transmission based on alternate arm converter (AAC) draws the attention of researchers due to their unique structure. It is a hybrid converter as the characteristics of this converter varies among the modular multilevel converter (MMC), due to...

Full description

Saved in:
Bibliographic Details
Main Authors: Faisal M., Das J., Shawon M., How D.N.T.
Other Authors: 57215018777
Format: Article
Published: Alpha Publishers 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833351030770761728
author Faisal M.
Das J.
Shawon M.
How D.N.T.
author2 57215018777
author_facet 57215018777
Faisal M.
Das J.
Shawon M.
How D.N.T.
author_sort Faisal M.
building UNITEN Library
collection Institutional Repository
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
continent Asia
country Malaysia
description Recent advancement of High Voltage Direct-Current (HVDC) transmission based on alternate arm converter (AAC) draws the attention of researchers due to their unique structure. It is a hybrid converter as the characteristics of this converter varies among the modular multilevel converter (MMC), due to the existence of H-bridge cells, and the two-level converter, in the sort of director switches in every arm of the converter. AAC presents the improved fault tolerant characteristics compare to traditional voltage source converter (VSC). It has gained much popularity in HVDC transmission because of its robustness against fault, ability of generating superior ac voltage compares to the dc terminal voltage. At this point energy balance between the ac and dc terminal is equal. Therefore, the significant contribution of this paper is to analyze the performance of AAC model under normal condition and fault condition which proves the robustness of AAC converter against the faulty situation. Both AC and DC faults are considered in this study. Simulation is performed in Matlab/ Simulink environment. � 2020 Alpha Publishers.
format Article
id my.uniten.dspace-25097
institution Universiti Tenaga Nasional
publishDate 2023
publisher Alpha Publishers
record_format dspace
spelling my.uniten.dspace-250972023-05-29T16:06:46Z Fault analysis of HVDC converter based on alternate arm converter topology Faisal M. Das J. Shawon M. How D.N.T. 57215018777 57193874478 57215325984 57212923888 Recent advancement of High Voltage Direct-Current (HVDC) transmission based on alternate arm converter (AAC) draws the attention of researchers due to their unique structure. It is a hybrid converter as the characteristics of this converter varies among the modular multilevel converter (MMC), due to the existence of H-bridge cells, and the two-level converter, in the sort of director switches in every arm of the converter. AAC presents the improved fault tolerant characteristics compare to traditional voltage source converter (VSC). It has gained much popularity in HVDC transmission because of its robustness against fault, ability of generating superior ac voltage compares to the dc terminal voltage. At this point energy balance between the ac and dc terminal is equal. Therefore, the significant contribution of this paper is to analyze the performance of AAC model under normal condition and fault condition which proves the robustness of AAC converter against the faulty situation. Both AC and DC faults are considered in this study. Simulation is performed in Matlab/ Simulink environment. � 2020 Alpha Publishers. Final 2023-05-29T08:06:46Z 2023-05-29T08:06:46Z 2020 Article 2-s2.0-85099160998 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85099160998&partnerID=40&md5=767123a66b467506adbaed4219a80806 https://irepository.uniten.edu.my/handle/123456789/25097 10 12 13467 13478 Alpha Publishers Scopus
spellingShingle Faisal M.
Das J.
Shawon M.
How D.N.T.
Fault analysis of HVDC converter based on alternate arm converter topology
title Fault analysis of HVDC converter based on alternate arm converter topology
title_full Fault analysis of HVDC converter based on alternate arm converter topology
title_fullStr Fault analysis of HVDC converter based on alternate arm converter topology
title_full_unstemmed Fault analysis of HVDC converter based on alternate arm converter topology
title_short Fault analysis of HVDC converter based on alternate arm converter topology
title_sort fault analysis of hvdc converter based on alternate arm converter topology
url_provider http://dspace.uniten.edu.my/