Neutron and gamma ray fluences measurement at radial Beam Port 1 of TRIGA MARK II PUSPATI research reactor

Diffraction; Diffractometers; Facilities; Neutron diffraction; Neutrons; Reactor shielding; Research reactors; Shielding; Beam ports; Facility designs; Fluences; Gamma dose rate; Neutron diffractometer; Research results; Shielding materials; TLD-700; Gamma rays

Saved in:
Bibliographic Details
Main Authors: Ashraff Rosdi M.A., Goh P.S., Idris F., Shalbi S., Sarkawi M.S., Mohd Ali N.S., Jamsari N.L., Ramli A.S., Azman A.
Other Authors: 57201211557
Format: Conference Paper
Published: Institute of Physics Publishing 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833351953061511168
author Ashraff Rosdi M.A.
Goh P.S.
Idris F.
Shalbi S.
Sarkawi M.S.
Mohd Ali N.S.
Jamsari N.L.
Ramli A.S.
Azman A.
author2 57201211557
author_facet 57201211557
Ashraff Rosdi M.A.
Goh P.S.
Idris F.
Shalbi S.
Sarkawi M.S.
Mohd Ali N.S.
Jamsari N.L.
Ramli A.S.
Azman A.
author_sort Ashraff Rosdi M.A.
building UNITEN Library
collection Institutional Repository
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
continent Asia
country Malaysia
description Diffraction; Diffractometers; Facilities; Neutron diffraction; Neutrons; Reactor shielding; Research reactors; Shielding; Beam ports; Facility designs; Fluences; Gamma dose rate; Neutron diffractometer; Research results; Shielding materials; TLD-700; Gamma rays
format Conference Paper
id my.uniten.dspace-23904
institution Universiti Tenaga Nasional
publishDate 2023
publisher Institute of Physics Publishing
record_format dspace
spelling my.uniten.dspace-239042023-05-29T14:53:00Z Neutron and gamma ray fluences measurement at radial Beam Port 1 of TRIGA MARK II PUSPATI research reactor Ashraff Rosdi M.A. Goh P.S. Idris F. Shalbi S. Sarkawi M.S. Mohd Ali N.S. Jamsari N.L. Ramli A.S. Azman A. 57201211557 25823091000 6701397678 57201216174 57201210915 57201215175 57201214455 57201212314 24075556300 Diffraction; Diffractometers; Facilities; Neutron diffraction; Neutrons; Reactor shielding; Research reactors; Shielding; Beam ports; Facility designs; Fluences; Gamma dose rate; Neutron diffractometer; Research results; Shielding materials; TLD-700; Gamma rays Neutron and gamma ray fluences are the important criteria to be looked at in a neutron diffractometer system facility design. The fluence is defined as the number of neutrons and gamma rays travel through a unit area. Currently, the facility for neutron diffractometer system are planned to be developed at radial beam port 1 of TRIGA MARK II PUSPATI research reactor (RTP). The aim of this research is to determine the value of neutron and gamma ray fluences produced at the end of radial beam port 1 and to identify the shielding materials suitable for neutron and gamma ray. In order to achieve this aim, an experiment has been designed to obtain the neutron and gamma dose rates by using TLD-600 and TLD-700. The results from this experiments are converted into neutron and gamma ray fluences and are then compared with the results from simulation. The comparison shows that both results meet an agreement on the feasibility of shielding material for neutron diffractometer system. Our research results may be of help in the design of shielding material for neutron diffractometer facility at RTP. � Published under licence by IOP Publishing Ltd. Final 2023-05-29T06:53:00Z 2023-05-29T06:53:00Z 2018 Conference Paper 10.1088/1757-899X/298/1/012033 2-s2.0-85043992588 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85043992588&doi=10.1088%2f1757-899X%2f298%2f1%2f012033&partnerID=40&md5=53293827e497dfab90b986d8912893dc https://irepository.uniten.edu.my/handle/123456789/23904 298 1 12033 All Open Access, Bronze Institute of Physics Publishing Scopus
spellingShingle Ashraff Rosdi M.A.
Goh P.S.
Idris F.
Shalbi S.
Sarkawi M.S.
Mohd Ali N.S.
Jamsari N.L.
Ramli A.S.
Azman A.
Neutron and gamma ray fluences measurement at radial Beam Port 1 of TRIGA MARK II PUSPATI research reactor
title Neutron and gamma ray fluences measurement at radial Beam Port 1 of TRIGA MARK II PUSPATI research reactor
title_full Neutron and gamma ray fluences measurement at radial Beam Port 1 of TRIGA MARK II PUSPATI research reactor
title_fullStr Neutron and gamma ray fluences measurement at radial Beam Port 1 of TRIGA MARK II PUSPATI research reactor
title_full_unstemmed Neutron and gamma ray fluences measurement at radial Beam Port 1 of TRIGA MARK II PUSPATI research reactor
title_short Neutron and gamma ray fluences measurement at radial Beam Port 1 of TRIGA MARK II PUSPATI research reactor
title_sort neutron and gamma ray fluences measurement at radial beam port 1 of triga mark ii puspati research reactor
url_provider http://dspace.uniten.edu.my/