A Compact Dual-Mode Dual-Band BPF Based Meander Square Resonator

Aluminum alloys; Medical applications; Microwave resonators; Dual Band; Dual band response; Dual modes; Impedance techniques; Microwave bandpass filter; Square resonators; Transmission zeros; tunable; Bandpass filters

Saved in:
Bibliographic Details
Main Author: Alqaisy M.
Other Authors: 55885807000
Format: Conference Paper
Published: Institute of Electrical and Electronics Engineers Inc. 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833410335240880128
author Alqaisy M.
author2 55885807000
author_facet 55885807000
Alqaisy M.
author_sort Alqaisy M.
building UNITEN Library
collection Institutional Repository
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
continent Asia
country Malaysia
description Aluminum alloys; Medical applications; Microwave resonators; Dual Band; Dual band response; Dual modes; Impedance techniques; Microwave bandpass filter; Square resonators; Transmission zeros; tunable; Bandpass filters
format Conference Paper
id my.uniten.dspace-23157
institution Universiti Tenaga Nasional
publishDate 2023
publisher Institute of Electrical and Electronics Engineers Inc.
record_format dspace
spelling my.uniten.dspace-231572023-05-29T14:38:04Z A Compact Dual-Mode Dual-Band BPF Based Meander Square Resonator Alqaisy M. 55885807000 Aluminum alloys; Medical applications; Microwave resonators; Dual Band; Dual band response; Dual modes; Impedance techniques; Microwave bandpass filter; Square resonators; Transmission zeros; tunable; Bandpass filters A tunable dual-band dual-mode microwave bandpass filter (BPF) with compact size is suggested using meander stepped impedance square loop resonator (SIR). A new scheme exhibited miniaturization more than 58 % compared to Euclidean microstrip loop resonator. A small patch was attached in one corner of a square loop resonator to degenerate dual mode configurations. On the other hand, a step impedance technique was utilized to tune the second band of the suggested BPF. Dual mode dual band responses are located at the medical applications (2.45 GHz) with -40 dB as a return loss and two transmission zeroes for sharp skirt response as a first band and also a tunable band from (4-5 GHz) for LTE applications with return loss less than -10 dB as a second band. To validate this structure design and analysis, CST computer simulation package was used. The dual mode simulation results have been extracted and compared with the literature which finding closed to each other. So that, CST simulator certified and can be adopted it for extracting a tunable dual-band results which have been achieved using a mentioned simulator. � 2017 IEEE. Final 2023-05-29T06:38:04Z 2023-05-29T06:38:04Z 2017 Conference Paper 10.1109/AIC-MITCSA.2017.8722958 2-s2.0-85067112148 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85067112148&doi=10.1109%2fAIC-MITCSA.2017.8722958&partnerID=40&md5=2226d00f7cd20e6391c3436e83a8dc59 https://irepository.uniten.edu.my/handle/123456789/23157 8722958 283 286 Institute of Electrical and Electronics Engineers Inc. Scopus
spellingShingle Alqaisy M.
A Compact Dual-Mode Dual-Band BPF Based Meander Square Resonator
title A Compact Dual-Mode Dual-Band BPF Based Meander Square Resonator
title_full A Compact Dual-Mode Dual-Band BPF Based Meander Square Resonator
title_fullStr A Compact Dual-Mode Dual-Band BPF Based Meander Square Resonator
title_full_unstemmed A Compact Dual-Mode Dual-Band BPF Based Meander Square Resonator
title_short A Compact Dual-Mode Dual-Band BPF Based Meander Square Resonator
title_sort compact dual-mode dual-band bpf based meander square resonator
url_provider http://dspace.uniten.edu.my/