Investigate the indoor air quality in store room

This thesis presents a study on Indoor Air Quality (IAQ) of store rooms in administration building. This study was conducted to determine and analyse the IAQ parameters in respected store rooms. The IAQ parameter assessed in this study are temperature, air velocity, relative humidity, carbon dioxide...

Full description

Saved in:
Bibliographic Details
Main Author: Harivin Raj A /l Mohan
Format:
Published: 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1840843380720926720
author Harivin Raj A /l Mohan
author_facet Harivin Raj A /l Mohan
author_sort Harivin Raj A /l Mohan
building UNITEN Library
collection Institutional Repository
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
continent Asia
country Malaysia
description This thesis presents a study on Indoor Air Quality (IAQ) of store rooms in administration building. This study was conducted to determine and analyse the IAQ parameters in respected store rooms. The IAQ parameter assessed in this study are temperature, air velocity, relative humidity, carbon dioxide (CO₂) and particulates (PM₁₀). The samplings were taken three times in a day by using several measurements instrument which are particle counter model CEM DT-9883M and anemometer model LM-8000. Average reading of IAQ parameters were analysed with the acceptable range and limit provided by Department of Occupational Safety and Health (DOSH) in Industry Code of Practice on Indoor Air Quality. The analysed data shows that, second floor store room has good indoor air quality and basement store room has higher level of relative humidity than acceptable maximum range. It is due to the water leakage problem in basement floor and improper ventilation system. Recommendations to improve the IAQ of store rooms was also presented in this study. By eliminating the identified source of contamination, the IAQ of store rooms can be improved. Implementations like removal of contaminated building products and installation of filtration system in mechanical ventilation can improve the air quality of indoor space
format
id my.uniten.dspace-21685
institution Universiti Tenaga Nasional
publishDate 2023
record_format dspace
spelling my.uniten.dspace-216852025-08-14T16:39:18Z Investigate the indoor air quality in store room Harivin Raj A /l Mohan indoor air quality store room pollutans This thesis presents a study on Indoor Air Quality (IAQ) of store rooms in administration building. This study was conducted to determine and analyse the IAQ parameters in respected store rooms. The IAQ parameter assessed in this study are temperature, air velocity, relative humidity, carbon dioxide (CO₂) and particulates (PM₁₀). The samplings were taken three times in a day by using several measurements instrument which are particle counter model CEM DT-9883M and anemometer model LM-8000. Average reading of IAQ parameters were analysed with the acceptable range and limit provided by Department of Occupational Safety and Health (DOSH) in Industry Code of Practice on Indoor Air Quality. The analysed data shows that, second floor store room has good indoor air quality and basement store room has higher level of relative humidity than acceptable maximum range. It is due to the water leakage problem in basement floor and improper ventilation system. Recommendations to improve the IAQ of store rooms was also presented in this study. By eliminating the identified source of contamination, the IAQ of store rooms can be improved. Implementations like removal of contaminated building products and installation of filtration system in mechanical ventilation can improve the air quality of indoor space 2023-05-03T17:40:01Z 2023-05-03T17:40:01Z 2020-02 https://irepository.uniten.edu.my/handle/123456789/21685 application/pdf
spellingShingle indoor air quality
store room
pollutans
Harivin Raj A /l Mohan
Investigate the indoor air quality in store room
title Investigate the indoor air quality in store room
title_full Investigate the indoor air quality in store room
title_fullStr Investigate the indoor air quality in store room
title_full_unstemmed Investigate the indoor air quality in store room
title_short Investigate the indoor air quality in store room
title_sort investigate the indoor air quality in store room
topic indoor air quality
store room
pollutans
url_provider http://dspace.uniten.edu.my/