The Utility Of 1-Minute Sit-To-Stand Test to Detect Exercise-Induced Oxygen Desaturation in Outpatient Assessment of Post COVID-19 Patients
Introduction: 6-min-walk-test (6MWT) is the gold standard for assessing exercise-induced impairment of gas exchange, but it is technically challenging in a busy outpatient clinic. The aim of this study was to compare the 1-minute sit-to-stand test (1MSTST) with the 6MWT in assessment of exercise-ind...
Saved in:
| Main Authors: | , , , |
|---|---|
| Format: | Article |
| Language: | en |
| Published: |
Faculty of Medicine, UiTM
2024
|
| Subjects: | |
| Online Access: | http://ir.unimas.my/id/eprint/44421/3/The%20Utility.pdf http://ir.unimas.my/id/eprint/44421/ https://jchs-medicine.uitm.edu.my/images/manuscript/vol9issue1/3.original-articles/3/3OA-The-Utility-Of-1-Minute-Sit-To-Stand-Test.pdf https://doi.org/10.24191/jchs.v9i1.21407 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Summary: | Introduction: 6-min-walk-test (6MWT) is the gold standard for assessing exercise-induced impairment of gas exchange, but it is technically challenging in a busy outpatient clinic. The aim of this study was to compare the 1-minute sit-to-stand test (1MSTST) with the 6MWT in assessment of exercise-induced oxygen desaturation in post COVID-19 patients in an outpatient setting. Methods: A total of 447 outpatient post COVID-19 patients were recruited
from post COVID-19 clinic. A set of 6MWT and 1MSTST were performed on the same day.
Results: A total of 447 sets were performed at a mean of 160 days post discharge. Majority were in COVID-19 infection category 4 (n=251, 56%), 5 (n=118, 26%) and 3 (n=6, 15%). A
total of 19% (n=89) of patients remained symptomatic (mMRC >1). There were no significant differences between nadir SpO2 of 6MWT and 1STST (p=0.075). Bland-Altman plots showed
good agreement between nadir SpO2 for 6MWT and 1MSTST (Mean differences=0.028).
1MSTST could detect oxygen desaturation >4% with sensitivity of 76.8% and specificity of 42.4% compared to 6MWT. There was no clinically significant SpO2 difference during 6MWT
and 1STS between symptomatic and asymptomatic patients at baseline, nadir, and recovery; the differences were <1%. However, there were lesser 6MWT distance and 1MSTST repetition between symptomatic and asymptomatic patients; 47m (p < 0.001) and 3 repetition (p < 0.001) respectively. Conclusion: There is a good agreement of nadir SpO2 and sensitivity to detect oxygen desaturation > 4% between 6MWT and 1MSTST. 1MSTST is a useful screening test to screen exercise-induced oxygen desaturation during outpatient assessment. |
|---|
