Design and development of real-time particulate matter measuring instrument applying laser scattering technique for microenvironment monitoring

Particulate Matter (PM) is one of the key indicators in determining Air Quality Index (AQI). While PM has been has identified as one of global health threat by the World Health Organization (WHO), and there is an urgent need for routine air monitoring data on components of the PM mass to identify th...

Full description

Saved in:
Bibliographic Details
Main Author: Angelo Sean Francis Tiwon
Format: Thesis
Language:en
en
Published: 2020
Subjects:
Online Access:https://eprints.ums.edu.my/id/eprint/40687/1/24%20PAGES.pdf
https://eprints.ums.edu.my/id/eprint/40687/2/FULLTEXT.pdf
https://eprints.ums.edu.my/id/eprint/40687/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1831796327517782016
author Angelo Sean Francis Tiwon
author_facet Angelo Sean Francis Tiwon
author_sort Angelo Sean Francis Tiwon
building UMS Library
collection Institutional Repository
content_provider Universiti Malaysia Sabah
content_source UMS Institutional Repository
continent Asia
country Malaysia
description Particulate Matter (PM) is one of the key indicators in determining Air Quality Index (AQI). While PM has been has identified as one of global health threat by the World Health Organization (WHO), and there is an urgent need for routine air monitoring data on components of the PM mass to identify the role of PM chemical components in causing adverse health effects for exposure control, assessment of particle exposure on a more personal level are not achievable by the conventional method due to their high cost and relatively large size. Therefore, it is crucial to have a better approach in monitoring particulate matter that can provide better spatial and temporal coverage which is made possible with the emergence of low-cost PM sensor. In this study a real time particulate matter measuring instrument applying laser scattering technique was developed and evaluated. Based on the evaluation, PMSA003 was selected as the best sensor to be applied in this PM monitoring instrument due to its high linearity response with reference instruments with R2>0.9 and low intra-model variability of 17.71%. A humidity correction algorithm was developed based on the climate susceptibility test as it was observed there are strong correlation between the reported mass concentration and humidity at more than 65 %RH. To further improve the performance of the instrument, it was deployed in three ambient setting where the density factor for the conversion of particle distribution to mass concentration was obtained for the indoor, outdoor and factory setting. The finalized prototype was validated with the Thermo Scientific™ 1405 TEOM™ Continuous Ambient Particulate Monitor. TOEM is certified Federal Equivalent Method (FEM) instrument by US. Through the field deployment, the prototype showed high correlation with the reference instrument with R2 > 0.9332 for PM2.5 and R2 >0.7623 for PM10.0. In conclusion, an integrated real time particulate matter measuring instrument was designed, developed and evaluated where the term design is referring to the whole system design. The developed instrument shows excellent correlation with reference instruments thus validating its potential to be applied for real life application.
format Thesis
id my.ums.eprints-40687
institution Universiti Malaysia Sabah
language en
en
publishDate 2020
record_format eprints
spelling my.ums.eprints-406872024-10-01T02:06:38Z https://eprints.ums.edu.my/id/eprint/40687/ Design and development of real-time particulate matter measuring instrument applying laser scattering technique for microenvironment monitoring Angelo Sean Francis Tiwon QH540-549.5 Ecology Particulate Matter (PM) is one of the key indicators in determining Air Quality Index (AQI). While PM has been has identified as one of global health threat by the World Health Organization (WHO), and there is an urgent need for routine air monitoring data on components of the PM mass to identify the role of PM chemical components in causing adverse health effects for exposure control, assessment of particle exposure on a more personal level are not achievable by the conventional method due to their high cost and relatively large size. Therefore, it is crucial to have a better approach in monitoring particulate matter that can provide better spatial and temporal coverage which is made possible with the emergence of low-cost PM sensor. In this study a real time particulate matter measuring instrument applying laser scattering technique was developed and evaluated. Based on the evaluation, PMSA003 was selected as the best sensor to be applied in this PM monitoring instrument due to its high linearity response with reference instruments with R2>0.9 and low intra-model variability of 17.71%. A humidity correction algorithm was developed based on the climate susceptibility test as it was observed there are strong correlation between the reported mass concentration and humidity at more than 65 %RH. To further improve the performance of the instrument, it was deployed in three ambient setting where the density factor for the conversion of particle distribution to mass concentration was obtained for the indoor, outdoor and factory setting. The finalized prototype was validated with the Thermo Scientific™ 1405 TEOM™ Continuous Ambient Particulate Monitor. TOEM is certified Federal Equivalent Method (FEM) instrument by US. Through the field deployment, the prototype showed high correlation with the reference instrument with R2 > 0.9332 for PM2.5 and R2 >0.7623 for PM10.0. In conclusion, an integrated real time particulate matter measuring instrument was designed, developed and evaluated where the term design is referring to the whole system design. The developed instrument shows excellent correlation with reference instruments thus validating its potential to be applied for real life application. 2020 Thesis NonPeerReviewed text en https://eprints.ums.edu.my/id/eprint/40687/1/24%20PAGES.pdf text en https://eprints.ums.edu.my/id/eprint/40687/2/FULLTEXT.pdf Angelo Sean Francis Tiwon (2020) Design and development of real-time particulate matter measuring instrument applying laser scattering technique for microenvironment monitoring. Masters thesis, Universiti Malaysia Sabah.
spellingShingle QH540-549.5 Ecology
Angelo Sean Francis Tiwon
Design and development of real-time particulate matter measuring instrument applying laser scattering technique for microenvironment monitoring
title Design and development of real-time particulate matter measuring instrument applying laser scattering technique for microenvironment monitoring
title_full Design and development of real-time particulate matter measuring instrument applying laser scattering technique for microenvironment monitoring
title_fullStr Design and development of real-time particulate matter measuring instrument applying laser scattering technique for microenvironment monitoring
title_full_unstemmed Design and development of real-time particulate matter measuring instrument applying laser scattering technique for microenvironment monitoring
title_short Design and development of real-time particulate matter measuring instrument applying laser scattering technique for microenvironment monitoring
title_sort design and development of real-time particulate matter measuring instrument applying laser scattering technique for microenvironment monitoring
topic QH540-549.5 Ecology
url https://eprints.ums.edu.my/id/eprint/40687/1/24%20PAGES.pdf
https://eprints.ums.edu.my/id/eprint/40687/2/FULLTEXT.pdf
https://eprints.ums.edu.my/id/eprint/40687/
url_provider http://eprints.ums.edu.my/