A modern refrigeration system consists of four main components which is a compressor, a condenser, an evaporator and a throttling device. There are many researches which have been conducted in order to achieve good performance of the refrigeration system such as two stage refrigeration system, energ...

Full description

Saved in:
Bibliographic Details
Main Author: Loh, Wing Liong
Format: Undergraduates Project Papers
Language:en
Published: 2012
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/6529/1/Performance%20of%20refrigerator%20operating%20with%20and%20without%20liquid-suction%20heating.pdf
http://umpir.ump.edu.my/id/eprint/6529/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1831521979172126720
author Loh, Wing Liong
author_facet Loh, Wing Liong
author_sort Loh, Wing Liong
building UMPSA Library
collection Institutional Repository
content_provider Universiti Malaysia Pahang Al-Sultan Abdullah
content_source UMPSA Institutional Repository
continent Asia
country Malaysia
description A modern refrigeration system consists of four main components which is a compressor, a condenser, an evaporator and a throttling device. There are many researches which have been conducted in order to achieve good performance of the refrigeration system such as two stage refrigeration system, energy systems and suction heating. Suction heating is based on the concept of heat transfer between the capillary tube and suction tube. Suction heating is applied in order to absorb heat and thus lowering the temperature if the refrigerant at the capillary tube. The main purpose of this project is to investigate the performance of refrigeration operating with and without liquid suction heating in order to investigate how much the suction heating influence the performance of the refrigeration system. The project is based on experimental study on refrigeration system test rig and two setup of experimental studies which is the experimental setup for refrigeration operating with suction heating and experimental setup for refrigeration operating without suction heating. Both sets of system configuration will be run until it reaches steady operating condition before data is collected in order to calculate the coefficient of performance (COP). Results show that the refrigeration system operating with liquid suction heating has the highest value of COP which is 2.14 compare with the system operating without suction heating which is 1.8. The percentage difference in COP is about 15.89 percent.
format Undergraduates Project Papers
id my.ump.umpir.6529
institution Universiti Malaysia Pahang
language en
publishDate 2012
record_format eprints
spelling my.ump.umpir.65292023-11-01T07:02:04Z http://umpir.ump.edu.my/id/eprint/6529/ Performance of refrigerator operating with and without liquid-suction heating Loh, Wing Liong TJ Mechanical engineering and machinery A modern refrigeration system consists of four main components which is a compressor, a condenser, an evaporator and a throttling device. There are many researches which have been conducted in order to achieve good performance of the refrigeration system such as two stage refrigeration system, energy systems and suction heating. Suction heating is based on the concept of heat transfer between the capillary tube and suction tube. Suction heating is applied in order to absorb heat and thus lowering the temperature if the refrigerant at the capillary tube. The main purpose of this project is to investigate the performance of refrigeration operating with and without liquid suction heating in order to investigate how much the suction heating influence the performance of the refrigeration system. The project is based on experimental study on refrigeration system test rig and two setup of experimental studies which is the experimental setup for refrigeration operating with suction heating and experimental setup for refrigeration operating without suction heating. Both sets of system configuration will be run until it reaches steady operating condition before data is collected in order to calculate the coefficient of performance (COP). Results show that the refrigeration system operating with liquid suction heating has the highest value of COP which is 2.14 compare with the system operating without suction heating which is 1.8. The percentage difference in COP is about 15.89 percent. 2012-06 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/6529/1/Performance%20of%20refrigerator%20operating%20with%20and%20without%20liquid-suction%20heating.pdf Loh, Wing Liong (2012) Performance of refrigerator operating with and without liquid-suction heating. Faculty of Mechanical Engineering, Universiti Malaysia Pahang.
spellingShingle TJ Mechanical engineering and machinery
Loh, Wing Liong
Performance of refrigerator operating with and without liquid-suction heating
title Performance of refrigerator operating with and without liquid-suction heating
title_full Performance of refrigerator operating with and without liquid-suction heating
title_fullStr Performance of refrigerator operating with and without liquid-suction heating
title_full_unstemmed Performance of refrigerator operating with and without liquid-suction heating
title_short Performance of refrigerator operating with and without liquid-suction heating
title_sort performance of refrigerator operating with and without liquid-suction heating
topic TJ Mechanical engineering and machinery
url http://umpir.ump.edu.my/id/eprint/6529/1/Performance%20of%20refrigerator%20operating%20with%20and%20without%20liquid-suction%20heating.pdf
http://umpir.ump.edu.my/id/eprint/6529/
url_provider http://umpir.ump.edu.my/