Ultrasonic Guided Wave Method For Crack Detection In Buried Plastic Pipe

Plastic pipe are widely used in many fields for the fluid or gaseous product conveyance but basic components of a plastic material made it very sensitive to damage, which requires techniques for detecting damage reliable and efficient. Ultrasonic guided wave is a sensitive method based on propagatio...

Full description

Saved in:
Bibliographic Details
Main Authors: Wan Sofian, Wan Hamat, M. F., Ghazali, Priyandoko, Gigih
Format: Conference or Workshop Item
Language:en
Published: EDP Sciences 2016
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/14536/1/Ultrasonic%20Guided%20Wave%20Method%20For%20Crack%20Detection%20In%20Buried%20Plastic.pdf
http://umpir.ump.edu.my/id/eprint/14536/
http://dx.doi.org/10.1051/matecconf/20167400012
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1831523995402371072
author Wan Sofian, Wan Hamat
M. F., Ghazali
Priyandoko, Gigih
author_facet Wan Sofian, Wan Hamat
M. F., Ghazali
Priyandoko, Gigih
author_sort Wan Sofian, Wan Hamat
building UMPSA Library
collection Institutional Repository
content_provider Universiti Malaysia Pahang Al-Sultan Abdullah
content_source UMPSA Institutional Repository
continent Asia
country Malaysia
description Plastic pipe are widely used in many fields for the fluid or gaseous product conveyance but basic components of a plastic material made it very sensitive to damage, which requires techniques for detecting damage reliable and efficient. Ultrasonic guided wave is a sensitive method based on propagation of low-frequency excitation in solid structures for damage detection. Ultrasonic guided wave method are performed to investigate the effect of crack to the frequency signal using Fast Fourier Transform (FFT) analysis. This paper researched to determine performance of ultrasonic guided wave method in order to detect crack in buried pipeline. It was found that for an uncrack pipe, FFT analysis shows one peak which is the operating frequency by the piezoelectric actuator itself while the FFT analysis for single cracked pipe shows two peak which is the operating frequency by the piezoelectric actuator itself and the resultant frequency from the crack. For multi cracked pipe, the frequency signal shows more than two peak depend the number of crack. The results presented here may facilitate improvements in the accuracy and precision of pipeline crack detection.
format Conference or Workshop Item
id my.ump.umpir.14536
institution Universiti Malaysia Pahang
language en
publishDate 2016
publisher EDP Sciences
record_format eprints
spelling my.ump.umpir.145362018-01-12T02:21:32Z http://umpir.ump.edu.my/id/eprint/14536/ Ultrasonic Guided Wave Method For Crack Detection In Buried Plastic Pipe Wan Sofian, Wan Hamat M. F., Ghazali Priyandoko, Gigih TJ Mechanical engineering and machinery Plastic pipe are widely used in many fields for the fluid or gaseous product conveyance but basic components of a plastic material made it very sensitive to damage, which requires techniques for detecting damage reliable and efficient. Ultrasonic guided wave is a sensitive method based on propagation of low-frequency excitation in solid structures for damage detection. Ultrasonic guided wave method are performed to investigate the effect of crack to the frequency signal using Fast Fourier Transform (FFT) analysis. This paper researched to determine performance of ultrasonic guided wave method in order to detect crack in buried pipeline. It was found that for an uncrack pipe, FFT analysis shows one peak which is the operating frequency by the piezoelectric actuator itself while the FFT analysis for single cracked pipe shows two peak which is the operating frequency by the piezoelectric actuator itself and the resultant frequency from the crack. For multi cracked pipe, the frequency signal shows more than two peak depend the number of crack. The results presented here may facilitate improvements in the accuracy and precision of pipeline crack detection. EDP Sciences 2016 Conference or Workshop Item PeerReviewed application/pdf en cc_by http://umpir.ump.edu.my/id/eprint/14536/1/Ultrasonic%20Guided%20Wave%20Method%20For%20Crack%20Detection%20In%20Buried%20Plastic.pdf Wan Sofian, Wan Hamat and M. F., Ghazali and Priyandoko, Gigih (2016) Ultrasonic Guided Wave Method For Crack Detection In Buried Plastic Pipe. In: MATEC Web of Conferences: The 3rd International Conference on Mechanical Engineering Research (ICMER 2015) , 18-19 August 2015 , Zenith Hotel, Kuantan, Pahang, Malaysia. pp. 1-5., 74 (00012). ISSN 2261-236X (Published) http://dx.doi.org/10.1051/matecconf/20167400012
spellingShingle TJ Mechanical engineering and machinery
Wan Sofian, Wan Hamat
M. F., Ghazali
Priyandoko, Gigih
Ultrasonic Guided Wave Method For Crack Detection In Buried Plastic Pipe
title Ultrasonic Guided Wave Method For Crack Detection In Buried Plastic Pipe
title_full Ultrasonic Guided Wave Method For Crack Detection In Buried Plastic Pipe
title_fullStr Ultrasonic Guided Wave Method For Crack Detection In Buried Plastic Pipe
title_full_unstemmed Ultrasonic Guided Wave Method For Crack Detection In Buried Plastic Pipe
title_short Ultrasonic Guided Wave Method For Crack Detection In Buried Plastic Pipe
title_sort ultrasonic guided wave method for crack detection in buried plastic pipe
topic TJ Mechanical engineering and machinery
url http://umpir.ump.edu.my/id/eprint/14536/1/Ultrasonic%20Guided%20Wave%20Method%20For%20Crack%20Detection%20In%20Buried%20Plastic.pdf
http://umpir.ump.edu.my/id/eprint/14536/
http://dx.doi.org/10.1051/matecconf/20167400012
url_provider http://umpir.ump.edu.my/