A biomedical engineering design for knee and elbow rehabilitation

Living in the modern era, there are many advancements being made in efforts to assist in the rehabilitation of patients with knee and elbow injuries. Among many problems faced by such patients, one of the most common is the restricted range of motion in knee and elbow. Restricted range of motion lim...

Full description

Saved in:
Bibliographic Details
Main Authors: Ramalingam, Mritha, Chinnavan, Elanchezhian, Puviarasi, R., Ramalingam, Ezhilarasu
Format: Conference or Workshop Item
Language:en
Published: Association for Computing Machinery 2020
Subjects:
Online Access:https://umpir.ump.edu.my/id/eprint/46794/1/A%20biomedical%20engineering%20design%20for%20knee%20and%20elbow%20rehabilitation.pdf
https://umpir.ump.edu.my/id/eprint/46794/
https://doi.org/10.1145/3397391.3397444
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1854094128507256832
author Ramalingam, Mritha
Chinnavan, Elanchezhian
Puviarasi, R.
Ramalingam, Ezhilarasu
author_facet Ramalingam, Mritha
Chinnavan, Elanchezhian
Puviarasi, R.
Ramalingam, Ezhilarasu
author_sort Ramalingam, Mritha
building UMPSA Library
collection Institutional Repository
content_provider Universiti Malaysia Pahang Al-Sultan Abdullah
content_source UMPSA Institutional Repository
continent Asia
country Malaysia
description Living in the modern era, there are many advancements being made in efforts to assist in the rehabilitation of patients with knee and elbow injuries. Among many problems faced by such patients, one of the most common is the restricted range of motion in knee and elbow. Restricted range of motion limits the execution of the smooth functional activity that lead to complications such as contractures, muscle weakness, and muscle tightness. Hence, the main objective of this paper is to design an automated comprehensive biomedical device for knee and elbow rehabilitation. This paper describes the design of biomedical device to measure the range of motion of patients' knee and elbow. The main feature of the proposed device is that it is able to be utilized throughout the rehabilitation duration, from regaining range of motion, to strengthening of the muscular components, and finally return to the normal elbow or knee function. The successful completion of this design will provide a biomedical engineering aid that would allow patients to progressively achieve the functional range of motion with tolerable pain.
format Conference or Workshop Item
id my.ump.umpir-46794
institution Universiti Malaysia Pahang
language en
publishDate 2020
publisher Association for Computing Machinery
record_format eprints
spelling my.ump.umpir-467942026-01-08T08:25:27Z https://umpir.ump.edu.my/id/eprint/46794/ A biomedical engineering design for knee and elbow rehabilitation Ramalingam, Mritha Chinnavan, Elanchezhian Puviarasi, R. Ramalingam, Ezhilarasu RC Internal medicine TA Engineering (General). Civil engineering (General) Living in the modern era, there are many advancements being made in efforts to assist in the rehabilitation of patients with knee and elbow injuries. Among many problems faced by such patients, one of the most common is the restricted range of motion in knee and elbow. Restricted range of motion limits the execution of the smooth functional activity that lead to complications such as contractures, muscle weakness, and muscle tightness. Hence, the main objective of this paper is to design an automated comprehensive biomedical device for knee and elbow rehabilitation. This paper describes the design of biomedical device to measure the range of motion of patients' knee and elbow. The main feature of the proposed device is that it is able to be utilized throughout the rehabilitation duration, from regaining range of motion, to strengthening of the muscular components, and finally return to the normal elbow or knee function. The successful completion of this design will provide a biomedical engineering aid that would allow patients to progressively achieve the functional range of motion with tolerable pain. Association for Computing Machinery 2020 Conference or Workshop Item PeerReviewed pdf en https://umpir.ump.edu.my/id/eprint/46794/1/A%20biomedical%20engineering%20design%20for%20knee%20and%20elbow%20rehabilitation.pdf Ramalingam, Mritha and Chinnavan, Elanchezhian and Puviarasi, R. and Ramalingam, Ezhilarasu (2020) A biomedical engineering design for knee and elbow rehabilitation. In: ACM International Conference Proceeding Series. 10th International Conference on Biomedical Engineering and Technology, ICBET 2020 , 15-18 Sept 2020 , Tokyo, Japan. pp. 247-252.. ISBN 9781450377249 (Published) https://doi.org/10.1145/3397391.3397444
spellingShingle RC Internal medicine
TA Engineering (General). Civil engineering (General)
Ramalingam, Mritha
Chinnavan, Elanchezhian
Puviarasi, R.
Ramalingam, Ezhilarasu
A biomedical engineering design for knee and elbow rehabilitation
title A biomedical engineering design for knee and elbow rehabilitation
title_full A biomedical engineering design for knee and elbow rehabilitation
title_fullStr A biomedical engineering design for knee and elbow rehabilitation
title_full_unstemmed A biomedical engineering design for knee and elbow rehabilitation
title_short A biomedical engineering design for knee and elbow rehabilitation
title_sort biomedical engineering design for knee and elbow rehabilitation
topic RC Internal medicine
TA Engineering (General). Civil engineering (General)
url https://umpir.ump.edu.my/id/eprint/46794/1/A%20biomedical%20engineering%20design%20for%20knee%20and%20elbow%20rehabilitation.pdf
https://umpir.ump.edu.my/id/eprint/46794/
https://doi.org/10.1145/3397391.3397444
url_provider http://umpir.ump.edu.my/