A biomedical engineering design for knee and elbow rehabilitation
Living in the modern era, there are many advancements being made in efforts to assist in the rehabilitation of patients with knee and elbow injuries. Among many problems faced by such patients, one of the most common is the restricted range of motion in knee and elbow. Restricted range of motion lim...
Saved in:
| Main Authors: | , , , |
|---|---|
| Format: | Conference or Workshop Item |
| Language: | en |
| Published: |
Association for Computing Machinery
2020
|
| Subjects: | |
| Online Access: | https://umpir.ump.edu.my/id/eprint/46794/1/A%20biomedical%20engineering%20design%20for%20knee%20and%20elbow%20rehabilitation.pdf https://umpir.ump.edu.my/id/eprint/46794/ https://doi.org/10.1145/3397391.3397444 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1854094128507256832 |
|---|---|
| author | Ramalingam, Mritha Chinnavan, Elanchezhian Puviarasi, R. Ramalingam, Ezhilarasu |
| author_facet | Ramalingam, Mritha Chinnavan, Elanchezhian Puviarasi, R. Ramalingam, Ezhilarasu |
| author_sort | Ramalingam, Mritha |
| building | UMPSA Library |
| collection | Institutional Repository |
| content_provider | Universiti Malaysia Pahang Al-Sultan Abdullah |
| content_source | UMPSA Institutional Repository |
| continent | Asia |
| country | Malaysia |
| description | Living in the modern era, there are many advancements being made in efforts to assist in the rehabilitation of patients with knee and elbow injuries. Among many problems faced by such patients, one of the most common is the restricted range of motion in knee and elbow. Restricted range of motion limits the execution of the smooth functional activity that lead to complications such as contractures, muscle weakness, and muscle tightness. Hence, the main objective of this paper is to design an automated comprehensive biomedical device for knee and elbow rehabilitation. This paper describes the design of biomedical device to measure the range of motion of patients' knee and elbow. The main feature of the proposed device is that it is able to be utilized throughout the rehabilitation duration, from regaining range of motion, to strengthening of the muscular components, and finally return to the normal elbow or knee function. The successful completion of this design will provide a biomedical engineering aid that would allow patients to progressively achieve the functional range of motion with tolerable pain. |
| format | Conference or Workshop Item |
| id | my.ump.umpir-46794 |
| institution | Universiti Malaysia Pahang |
| language | en |
| publishDate | 2020 |
| publisher | Association for Computing Machinery |
| record_format | eprints |
| spelling | my.ump.umpir-467942026-01-08T08:25:27Z https://umpir.ump.edu.my/id/eprint/46794/ A biomedical engineering design for knee and elbow rehabilitation Ramalingam, Mritha Chinnavan, Elanchezhian Puviarasi, R. Ramalingam, Ezhilarasu RC Internal medicine TA Engineering (General). Civil engineering (General) Living in the modern era, there are many advancements being made in efforts to assist in the rehabilitation of patients with knee and elbow injuries. Among many problems faced by such patients, one of the most common is the restricted range of motion in knee and elbow. Restricted range of motion limits the execution of the smooth functional activity that lead to complications such as contractures, muscle weakness, and muscle tightness. Hence, the main objective of this paper is to design an automated comprehensive biomedical device for knee and elbow rehabilitation. This paper describes the design of biomedical device to measure the range of motion of patients' knee and elbow. The main feature of the proposed device is that it is able to be utilized throughout the rehabilitation duration, from regaining range of motion, to strengthening of the muscular components, and finally return to the normal elbow or knee function. The successful completion of this design will provide a biomedical engineering aid that would allow patients to progressively achieve the functional range of motion with tolerable pain. Association for Computing Machinery 2020 Conference or Workshop Item PeerReviewed pdf en https://umpir.ump.edu.my/id/eprint/46794/1/A%20biomedical%20engineering%20design%20for%20knee%20and%20elbow%20rehabilitation.pdf Ramalingam, Mritha and Chinnavan, Elanchezhian and Puviarasi, R. and Ramalingam, Ezhilarasu (2020) A biomedical engineering design for knee and elbow rehabilitation. In: ACM International Conference Proceeding Series. 10th International Conference on Biomedical Engineering and Technology, ICBET 2020 , 15-18 Sept 2020 , Tokyo, Japan. pp. 247-252.. ISBN 9781450377249 (Published) https://doi.org/10.1145/3397391.3397444 |
| spellingShingle | RC Internal medicine TA Engineering (General). Civil engineering (General) Ramalingam, Mritha Chinnavan, Elanchezhian Puviarasi, R. Ramalingam, Ezhilarasu A biomedical engineering design for knee and elbow rehabilitation |
| title | A biomedical engineering design for knee and elbow rehabilitation |
| title_full | A biomedical engineering design for knee and elbow rehabilitation |
| title_fullStr | A biomedical engineering design for knee and elbow rehabilitation |
| title_full_unstemmed | A biomedical engineering design for knee and elbow rehabilitation |
| title_short | A biomedical engineering design for knee and elbow rehabilitation |
| title_sort | biomedical engineering design for knee and elbow rehabilitation |
| topic | RC Internal medicine TA Engineering (General). Civil engineering (General) |
| url | https://umpir.ump.edu.my/id/eprint/46794/1/A%20biomedical%20engineering%20design%20for%20knee%20and%20elbow%20rehabilitation.pdf https://umpir.ump.edu.my/id/eprint/46794/ https://doi.org/10.1145/3397391.3397444 |
| url_provider | http://umpir.ump.edu.my/ |
