Optimisation of corona ring design and its impact on the performance of insulator string in high voltage transmission lines / Kalaiselvi Aramugam

Installation of a corona ring on an insulator string on a transmission line is one of the solutions to reduce the electric field stress surrounding the energised end of the insulator string. However, installing a corona ring with an optimum design to reduce the electric field magnitude on an insulat...

Full description

Saved in:
Bibliographic Details
Main Author: Kalaiselvi , Aramugam
Format: Thesis
Published: 2022
Subjects:
Online Access:http://studentsrepo.um.edu.my/14855/1/Kalaiselvi.pdf
http://studentsrepo.um.edu.my/14855/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1831436504352686080
author Kalaiselvi , Aramugam
author_facet Kalaiselvi , Aramugam
author_sort Kalaiselvi , Aramugam
building UM Library
collection Institutional Repository
content_provider Universiti Malaya
content_source UM Student Repository
continent Asia
country Malaysia
description Installation of a corona ring on an insulator string on a transmission line is one of the solutions to reduce the electric field stress surrounding the energised end of the insulator string. However, installing a corona ring with an optimum design to reduce the electric field magnitude on an insulator string is a challenging task. Therefore, in this work, a method to achieve an optimum design of a corona ring for a 33 kV and 132 kV composite non-ceramic insulator string was proposed using optimisation methods; Gravitational Search Algorithm (GSA), Imperialist Competitive Algorithm (ICA) and Grey Wolf Optimisation (GWO). The composite non-ceramic insulator string geometry with and without corona ring was modeled in finite element analysis and used to obtain the electric field distribution in the model geometry. The electric field distribution was evaluated using variation of corona ring dimensions, i.e. the ring diameter, the ring tube diameter and the vertical position of the ring along the insulator string. From the results achieved, comparison of the minimum electric field magnitude along the insulator string with a corona ring design shows that the minimum electric field magnitude is lower using optimisation techniques. Among the methods tested, the most suitable technique is found based on insulator model used in this work. Hence, this indicates the capability and effectiveness of the proposed methods in achieving an optimum design of a corona ring on an insulator string.
format Thesis
id my.um.stud-14855
institution Universiti Malaya
publishDate 2022
record_format eprints
spelling my.um.stud-148552024-03-19T22:31:52Z Optimisation of corona ring design and its impact on the performance of insulator string in high voltage transmission lines / Kalaiselvi Aramugam Kalaiselvi , Aramugam TK Electrical engineering. Electronics Nuclear engineering Installation of a corona ring on an insulator string on a transmission line is one of the solutions to reduce the electric field stress surrounding the energised end of the insulator string. However, installing a corona ring with an optimum design to reduce the electric field magnitude on an insulator string is a challenging task. Therefore, in this work, a method to achieve an optimum design of a corona ring for a 33 kV and 132 kV composite non-ceramic insulator string was proposed using optimisation methods; Gravitational Search Algorithm (GSA), Imperialist Competitive Algorithm (ICA) and Grey Wolf Optimisation (GWO). The composite non-ceramic insulator string geometry with and without corona ring was modeled in finite element analysis and used to obtain the electric field distribution in the model geometry. The electric field distribution was evaluated using variation of corona ring dimensions, i.e. the ring diameter, the ring tube diameter and the vertical position of the ring along the insulator string. From the results achieved, comparison of the minimum electric field magnitude along the insulator string with a corona ring design shows that the minimum electric field magnitude is lower using optimisation techniques. Among the methods tested, the most suitable technique is found based on insulator model used in this work. Hence, this indicates the capability and effectiveness of the proposed methods in achieving an optimum design of a corona ring on an insulator string. 2022-05 Thesis NonPeerReviewed application/pdf http://studentsrepo.um.edu.my/14855/1/Kalaiselvi.pdf Kalaiselvi , Aramugam (2022) Optimisation of corona ring design and its impact on the performance of insulator string in high voltage transmission lines / Kalaiselvi Aramugam. PhD thesis, Universiti Malaya. http://studentsrepo.um.edu.my/14855/
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Kalaiselvi , Aramugam
Optimisation of corona ring design and its impact on the performance of insulator string in high voltage transmission lines / Kalaiselvi Aramugam
title Optimisation of corona ring design and its impact on the performance of insulator string in high voltage transmission lines / Kalaiselvi Aramugam
title_full Optimisation of corona ring design and its impact on the performance of insulator string in high voltage transmission lines / Kalaiselvi Aramugam
title_fullStr Optimisation of corona ring design and its impact on the performance of insulator string in high voltage transmission lines / Kalaiselvi Aramugam
title_full_unstemmed Optimisation of corona ring design and its impact on the performance of insulator string in high voltage transmission lines / Kalaiselvi Aramugam
title_short Optimisation of corona ring design and its impact on the performance of insulator string in high voltage transmission lines / Kalaiselvi Aramugam
title_sort optimisation of corona ring design and its impact on the performance of insulator string in high voltage transmission lines / kalaiselvi aramugam
topic TK Electrical engineering. Electronics Nuclear engineering
url http://studentsrepo.um.edu.my/14855/1/Kalaiselvi.pdf
http://studentsrepo.um.edu.my/14855/
url_provider http://studentsrepo.um.edu.my/