Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman

The purpose of this study was to characterize specific dosimetric properties of Gafchromic HD-V2 film and to investigate its feasibility in the dosimetric verification for Stereotactic Radiosurgery (SRS). Basic dosimeter properties including energy and dose rate dependencies were investigated and...

Full description

Saved in:
Bibliographic Details
Main Author: Muhammad Taufiq, Azman
Format: Thesis
Published: 2018
Subjects:
Online Access:http://studentsrepo.um.edu.my/11570/4/taufiq.pdf
http://studentsrepo.um.edu.my/11570/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1831435844076961792
author Muhammad Taufiq, Azman
author_facet Muhammad Taufiq, Azman
author_sort Muhammad Taufiq, Azman
building UM Library
collection Institutional Repository
content_provider Universiti Malaya
content_source UM Student Repository
continent Asia
country Malaysia
description The purpose of this study was to characterize specific dosimetric properties of Gafchromic HD-V2 film and to investigate its feasibility in the dosimetric verification for Stereotactic Radiosurgery (SRS). Basic dosimeter properties including energy and dose rate dependencies were investigated and HD-V2 film showed energy and dose rate dependencies of less than 9.5% and 4.94% respectively. The HD-V2 film has very low dependency on scanning orientation in portrait versus landscape as well as “face-up” versus “face-down” scanning orientation. The percentage differences recorded were less than 2.7% for portrait versus landscape and less than 2.5% for “face-up” versus “facedown” orientation. In terms of angular dependency, there was no significant influence on net optical density, with deviations less than 4.3% for films irradiated at selected gantry angles ranging from 0° (which film is perpendicular to the irradiation beam) to 180°. Two treatment plans using SRS technique were created and irradiated using HD-V2 film for dosimetric verification. The dose distributions were calculated using a treatment planning system to obtain point doses at specified positions within a phantom. The calculated doses from TPS were compared to dose distributions delivered to HD-V2 film. The results of the point dose measurements for SRS treatment irradiations showed that the deviations between the TPS predicted dose and HD-V2 film measurements were less 4% which were within the recommended values by ICRU. This study shows that Gafchromic HD-V2 film can be used as dosimetric verification for SRS and for radiotherapy clinical practices that involves high range of doses of 10 to 1000 Gy
format Thesis
id my.um.stud-11570
institution Universiti Malaya
publishDate 2018
record_format eprints
spelling my.um.stud-115702020-08-25T18:57:57Z Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman Muhammad Taufiq, Azman R Medicine (General) The purpose of this study was to characterize specific dosimetric properties of Gafchromic HD-V2 film and to investigate its feasibility in the dosimetric verification for Stereotactic Radiosurgery (SRS). Basic dosimeter properties including energy and dose rate dependencies were investigated and HD-V2 film showed energy and dose rate dependencies of less than 9.5% and 4.94% respectively. The HD-V2 film has very low dependency on scanning orientation in portrait versus landscape as well as “face-up” versus “face-down” scanning orientation. The percentage differences recorded were less than 2.7% for portrait versus landscape and less than 2.5% for “face-up” versus “facedown” orientation. In terms of angular dependency, there was no significant influence on net optical density, with deviations less than 4.3% for films irradiated at selected gantry angles ranging from 0° (which film is perpendicular to the irradiation beam) to 180°. Two treatment plans using SRS technique were created and irradiated using HD-V2 film for dosimetric verification. The dose distributions were calculated using a treatment planning system to obtain point doses at specified positions within a phantom. The calculated doses from TPS were compared to dose distributions delivered to HD-V2 film. The results of the point dose measurements for SRS treatment irradiations showed that the deviations between the TPS predicted dose and HD-V2 film measurements were less 4% which were within the recommended values by ICRU. This study shows that Gafchromic HD-V2 film can be used as dosimetric verification for SRS and for radiotherapy clinical practices that involves high range of doses of 10 to 1000 Gy 2018 Thesis NonPeerReviewed application/pdf http://studentsrepo.um.edu.my/11570/4/taufiq.pdf Muhammad Taufiq, Azman (2018) Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman. Masters thesis, University of Malaya. http://studentsrepo.um.edu.my/11570/
spellingShingle R Medicine (General)
Muhammad Taufiq, Azman
Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman
title Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman
title_full Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman
title_fullStr Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman
title_full_unstemmed Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman
title_short Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman
title_sort characterization of gafchromic hd-v2 film for dose verification in stereotactic radiosurgery (srs) / muhammad taufiq azman
topic R Medicine (General)
url http://studentsrepo.um.edu.my/11570/4/taufiq.pdf
http://studentsrepo.um.edu.my/11570/
url_provider http://studentsrepo.um.edu.my/