Determination of capsaicin in different types of chilies {Capsicum Annuum) using solid phase microextraction (SPME) and gas chromatography mass spectrometry detector (GC-MSD) / Najid Seli

Determination of capsaicin in different types of chilies (Capsicum Annuum)were extracted by method of solid phase micro extraction (SPME) and then analyzed by gas chromatography with mass spectrometry detector (GCMSD).The optimizations of SPME were carried out in order to enhance the fiber performan...

Full description

Saved in:
Bibliographic Details
Main Author: Seli, Najid
Format: Student Project
Language:en
Published: 2009
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/72573/1/72573.PDF
https://ir.uitm.edu.my/id/eprint/72573/
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Determination of capsaicin in different types of chilies (Capsicum Annuum)were extracted by method of solid phase micro extraction (SPME) and then analyzed by gas chromatography with mass spectrometry detector (GCMSD).The optimizations of SPME were carried out in order to enhance the fiber performance and obtain high amount of capsaicin extracted. It was found that the optimum SPME conditions were at 50°C extraction temperature and 30 min extraction time. The direct immersion of SPME was applied to extract capsaicin from chilies. The result showed that Capsicumannuum var chili padi has the relatively highest concentration of capsaicin. This was followed by Capsicum annuum var chili kulai and Capsicumannuum var chili merah besar.