Bond strengths of composite resins used for the attachment of bonded retainers/ Saraswathy D Sinniah ... [et al.]

To compare the bond strengths and survival of flowable and non-flowable composite resins used with bonded retainers. Department of Orthodontics, UCL Eastman Dental Institute, United Kingdom. Flowable composite resins (TransbondTM Supreme LV, StarFlowTM and Tetric EvoFlow®) and non-flowable control r...

Full description

Saved in:
Bibliographic Details
Main Authors: Sinniah, Saraswathy D, Jones, Steven P, Georgiou, George, Cunningham, Susan J, Petrie, Aviva
Format: Article
Language:en
Published: Faculty of Dentistry 2016
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/48949/1/48949.pdf
https://ir.uitm.edu.my/id/eprint/48949/
https://journal.uitm.edu.my/ojs/index.php/COS/article/view/1823
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1842127846588284928
author Sinniah, Saraswathy D
Jones, Steven P
Georgiou, George
Cunningham, Susan J
Petrie, Aviva
author_facet Sinniah, Saraswathy D
Jones, Steven P
Georgiou, George
Cunningham, Susan J
Petrie, Aviva
author_sort Sinniah, Saraswathy D
building Tun Abdul Razak Library
collection Institutional Repository
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
continent Asia
country Malaysia
description To compare the bond strengths and survival of flowable and non-flowable composite resins used with bonded retainers. Department of Orthodontics, UCL Eastman Dental Institute, United Kingdom. Flowable composite resins (TransbondTM Supreme LV, StarFlowTM and Tetric EvoFlow®) and non-flowable control resin (TransbondTM LR) were made into cylinders prior to bonding to hydoxyapatite discs. They were then mounted into jigs and tested in the InstronTM Universal Testing Machine in both shear and tensile modes. The highest mean shear bond strength was seen with StarFlowTM (14.09 MPa), which was significantly higher than both TransbondTM LR (9.48 MPa) and TransbondTM Supreme LV (8.20 MPa). The mean shear bond strength of Tetric EvoFlow®(11.86 MPa) was also significantly higher than TransbondTM Supreme LV. The highest mean tensile bond strength was seen with Tetric EvoFlow®(2.14 MPa), which was significantly higher than TransbondTM LR (1.15 MPa) and TransbondTM Supreme LV (0.61 MPa) but not significantly different to StarFlowTM (1.47 MPa). For shear loading, StarFlowTM had the highest 50th percentile survival estimate at 15.10 MPa, followed by Tetric EvoFlow®(13.00 MPa) and TransbondTM Supreme LV (7.50 MPa). TransbondTM LR had a 50th percentile estimate at 9.00 MPa. For tensile loading, Tetric EvoFlow®had the highest 50th percentile survival estimate at 2.50 MPa, followed by StarFlowTM (1.30 MPa) and TransbondTM Supreme LV (0.50 MPa). TransbondTM LR had a 50th percentile estimate at 1.00 MPa. Mean shear bond strengths for all of the resins were significantly higher than the mean tensile bond strengths. StarFlowTM and Tetric EvoFlow®could potentially be suitable clinical alternatives to TransbondTM LR due to its low viscosity flow characteristics and adequate shear and tensile bond strengths.
format Article
id my.uitm.ir-48949
institution Universiti Teknologi Mara
language en
publishDate 2016
publisher Faculty of Dentistry
record_format eprints
spelling my.uitm.ir-489492025-08-28T04:08:34Z https://ir.uitm.edu.my/id/eprint/48949/ Bond strengths of composite resins used for the attachment of bonded retainers/ Saraswathy D Sinniah ... [et al.] cos Sinniah, Saraswathy D Jones, Steven P Georgiou, George Cunningham, Susan J Petrie, Aviva Oral and dental medicine. Pathology. Diseases Orthodontics To compare the bond strengths and survival of flowable and non-flowable composite resins used with bonded retainers. Department of Orthodontics, UCL Eastman Dental Institute, United Kingdom. Flowable composite resins (TransbondTM Supreme LV, StarFlowTM and Tetric EvoFlow®) and non-flowable control resin (TransbondTM LR) were made into cylinders prior to bonding to hydoxyapatite discs. They were then mounted into jigs and tested in the InstronTM Universal Testing Machine in both shear and tensile modes. The highest mean shear bond strength was seen with StarFlowTM (14.09 MPa), which was significantly higher than both TransbondTM LR (9.48 MPa) and TransbondTM Supreme LV (8.20 MPa). The mean shear bond strength of Tetric EvoFlow®(11.86 MPa) was also significantly higher than TransbondTM Supreme LV. The highest mean tensile bond strength was seen with Tetric EvoFlow®(2.14 MPa), which was significantly higher than TransbondTM LR (1.15 MPa) and TransbondTM Supreme LV (0.61 MPa) but not significantly different to StarFlowTM (1.47 MPa). For shear loading, StarFlowTM had the highest 50th percentile survival estimate at 15.10 MPa, followed by Tetric EvoFlow®(13.00 MPa) and TransbondTM Supreme LV (7.50 MPa). TransbondTM LR had a 50th percentile estimate at 9.00 MPa. For tensile loading, Tetric EvoFlow®had the highest 50th percentile survival estimate at 2.50 MPa, followed by StarFlowTM (1.30 MPa) and TransbondTM Supreme LV (0.50 MPa). TransbondTM LR had a 50th percentile estimate at 1.00 MPa. Mean shear bond strengths for all of the resins were significantly higher than the mean tensile bond strengths. StarFlowTM and Tetric EvoFlow®could potentially be suitable clinical alternatives to TransbondTM LR due to its low viscosity flow characteristics and adequate shear and tensile bond strengths. Faculty of Dentistry 2016 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/48949/1/48949.pdf Sinniah, Saraswathy D and Jones, Steven P and Georgiou, George and Cunningham, Susan J and Petrie, Aviva (2016) Bond strengths of composite resins used for the attachment of bonded retainers/ Saraswathy D Sinniah ... [et al.]. (2016) Compendium of Oral Science (COS) <https://ir.uitm.edu.my/view/publication/Compendium_of_Oral_Science_=28COS=29.html>, 3 (1): 3. pp. 17-24. ISSN 2489-1102; 2637-0611 https://journal.uitm.edu.my/ojs/index.php/COS/article/view/1823 10.24191/cos.v3i0.17515 10.24191/cos.v3i0.17515 10.24191/cos.v3i0.17515
spellingShingle Oral and dental medicine. Pathology. Diseases
Orthodontics
Sinniah, Saraswathy D
Jones, Steven P
Georgiou, George
Cunningham, Susan J
Petrie, Aviva
Bond strengths of composite resins used for the attachment of bonded retainers/ Saraswathy D Sinniah ... [et al.]
title Bond strengths of composite resins used for the attachment of bonded retainers/ Saraswathy D Sinniah ... [et al.]
title_full Bond strengths of composite resins used for the attachment of bonded retainers/ Saraswathy D Sinniah ... [et al.]
title_fullStr Bond strengths of composite resins used for the attachment of bonded retainers/ Saraswathy D Sinniah ... [et al.]
title_full_unstemmed Bond strengths of composite resins used for the attachment of bonded retainers/ Saraswathy D Sinniah ... [et al.]
title_short Bond strengths of composite resins used for the attachment of bonded retainers/ Saraswathy D Sinniah ... [et al.]
title_sort bond strengths of composite resins used for the attachment of bonded retainers/ saraswathy d sinniah ... [et al.]
topic Oral and dental medicine. Pathology. Diseases
Orthodontics
url https://ir.uitm.edu.my/id/eprint/48949/1/48949.pdf
https://ir.uitm.edu.my/id/eprint/48949/
https://journal.uitm.edu.my/ojs/index.php/COS/article/view/1823
url_provider http://ir.uitm.edu.my/