Development of novel distance relay scheme to prevent false tripping during power swing / Nor Zulaily Mohamad

Contingencies in a power system such as a sudden change of load, a power system fault, or a trip of large generation unit, may cause instability issue in which eventually may lead to the power swing phenomenon. During a power swing, the distance relay is prone to operate falsely and, as a result, th...

Full description

Saved in:
Bibliographic Details
Main Author: Mohamad, Nor Zulaily
Format: Book Section
Language:en
Published: Institute of Graduate Studies, UiTM 2017
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/19906/1/ABS_NOR%20ZULAILY%20MOHAMAD%20TDRA%20VOL%2012%20IGS%2017.pdf
https://ir.uitm.edu.my/id/eprint/19906/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833060710564757504
author Mohamad, Nor Zulaily
author_facet Mohamad, Nor Zulaily
author_sort Mohamad, Nor Zulaily
building Tun Abdul Razak Library
collection Institutional Repository
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
continent Asia
country Malaysia
description Contingencies in a power system such as a sudden change of load, a power system fault, or a trip of large generation unit, may cause instability issue in which eventually may lead to the power swing phenomenon. During a power swing, the distance relay is prone to operate falsely and, as a result, this false operation has often contributed to major power outages. Therefore, there is a need for development of a comprehensive protection scheme to improve sensitivity of the distance relay operation during power swing. The objectives of the research are to develop new intelligent schemes for preventing false relay operation during power swing. The initial work carried out in this study focuses on developing a new detection scheme that able to detect a fault that occurs during power swing. Another new detection scheme is also developed in this study for identifying the type of power swing. These two detection schemes are conceptually based on S-Transform feature extraction of the distance relay input signal. Moreover, a new adaptive distance protection algorithm is also developed to block the false tripping operation during power swing and unblock the operation if a fault occurs during power swing.
format Book Section
id my.uitm.ir-19906
institution Universiti Teknologi Mara
language en
publishDate 2017
publisher Institute of Graduate Studies, UiTM
record_format eprints
spelling my.uitm.ir-199062018-06-08T03:58:37Z https://ir.uitm.edu.my/id/eprint/19906/ Development of novel distance relay scheme to prevent false tripping during power swing / Nor Zulaily Mohamad Mohamad, Nor Zulaily Malaysia Contingencies in a power system such as a sudden change of load, a power system fault, or a trip of large generation unit, may cause instability issue in which eventually may lead to the power swing phenomenon. During a power swing, the distance relay is prone to operate falsely and, as a result, this false operation has often contributed to major power outages. Therefore, there is a need for development of a comprehensive protection scheme to improve sensitivity of the distance relay operation during power swing. The objectives of the research are to develop new intelligent schemes for preventing false relay operation during power swing. The initial work carried out in this study focuses on developing a new detection scheme that able to detect a fault that occurs during power swing. Another new detection scheme is also developed in this study for identifying the type of power swing. These two detection schemes are conceptually based on S-Transform feature extraction of the distance relay input signal. Moreover, a new adaptive distance protection algorithm is also developed to block the false tripping operation during power swing and unblock the operation if a fault occurs during power swing. Institute of Graduate Studies, UiTM 2017 Book Section PeerReviewed text en https://ir.uitm.edu.my/id/eprint/19906/1/ABS_NOR%20ZULAILY%20MOHAMAD%20TDRA%20VOL%2012%20IGS%2017.pdf Development of novel distance relay scheme to prevent false tripping during power swing / Nor Zulaily Mohamad. (2017) In: The Doctoral Research Abstracts. IGS Biannual Publication, 12 (12). Institute of Graduate Studies, UiTM, Shah Alam.
spellingShingle Malaysia
Mohamad, Nor Zulaily
Development of novel distance relay scheme to prevent false tripping during power swing / Nor Zulaily Mohamad
title Development of novel distance relay scheme to prevent false tripping during power swing / Nor Zulaily Mohamad
title_full Development of novel distance relay scheme to prevent false tripping during power swing / Nor Zulaily Mohamad
title_fullStr Development of novel distance relay scheme to prevent false tripping during power swing / Nor Zulaily Mohamad
title_full_unstemmed Development of novel distance relay scheme to prevent false tripping during power swing / Nor Zulaily Mohamad
title_short Development of novel distance relay scheme to prevent false tripping during power swing / Nor Zulaily Mohamad
title_sort development of novel distance relay scheme to prevent false tripping during power swing / nor zulaily mohamad
topic Malaysia
url https://ir.uitm.edu.my/id/eprint/19906/1/ABS_NOR%20ZULAILY%20MOHAMAD%20TDRA%20VOL%2012%20IGS%2017.pdf
https://ir.uitm.edu.my/id/eprint/19906/
url_provider http://ir.uitm.edu.my/