Effects of operating conditions on evaporation rate and wall shear stress development in a micro-gap heat sink with internal micro-fins

Evaporation in the micro-gap heat sink has a very high heat transfer coefficient. As a result, it is significant for high heat flux management. Heat transfer rate can be enhanced further by including internal micro-fins. However, the pressure drop penalty due to the small gap height and fin surfac...

Full description

Saved in:
Bibliographic Details
Main Authors: Ahmed, Shugata, Sulaeman, Erwin, Ismail, Ahmad Faris, Hasan, Muhammad Hasibul, Hanouf, Zahir
Format: Article
Language:en
Published: Semarak Ilmu Publishing 2022
Subjects:
Online Access:http://irep.iium.edu.my/97120/7/97120_Effects%20of%20operating%20conditions%20on%20evaporation%20rate.pdf
http://irep.iium.edu.my/97120/
https://semarakilmu.com.my/journals/index.php/CFD_Letters/article/view/327/190
https://doi.org/10.37934/cfdl.14.2.19
Tags: Add Tag
No Tags, Be the first to tag this record!