Seismic resistance evaluation of reinforced concrete (RC) exterior beam-column joints with and without GFRP under quasi-static lateral cyclic loading by adopting experimental analysis

The beam-column joint is an important component of Reinforced Concrete (RC) structures because its design and detailing are critical to the safety of these structures under seismic loading. In recent decades, structural behaviour of beam-column joints has been widely explored. To better understand t...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd Razmi Mohd Amit, Asma Nabila Abd. Kader, M.Y.M Yatim
Format: Article
Language:en
Published: Penerbit Universiti Kebangsaan Malaysia 2022
Online Access:http://journalarticle.ukm.my/21120/1/Jk_17.pdf
http://journalarticle.ukm.my/21120/
https://www.ukm.my/jkukm/volume-3406-2022/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1834434128866443264
author Mohd Razmi Mohd Amit,
Asma Nabila Abd. Kader,
M.Y.M Yatim,
author_facet Mohd Razmi Mohd Amit,
Asma Nabila Abd. Kader,
M.Y.M Yatim,
author_sort Mohd Razmi Mohd Amit,
building Tun Sri Lanang Library
collection Institutional Repository
content_provider Universiti Kebangsaan Malaysia
content_source UKM Journal Article Repository
continent Asia
country Malaysia
description The beam-column joint is an important component of Reinforced Concrete (RC) structures because its design and detailing are critical to the safety of these structures under seismic loading. In recent decades, structural behaviour of beam-column joints has been widely explored. To better understand the behaviour of beam-column joints, researchers have conducted experiments and provided analytical and experimental solutions. The seismic behaviour of beam-column joints with and without Glass Fibre Reinforced Polymer (GFRP) when subjected to quasi-static lateral cyclic loading was compared in this research using two specimens. The first specimen is a typical RC exterior beam-column joint without GFRP while the second specimen is RC exterior beam-column joint that is pre-installed with Glass Fibre Reinforced Polymer (GFRP) using Near-Surface Mounted (NSM) technique. The specimens were evaluated to a drift of 2.0% under quasi-static lateral cyclic loading. There were two cycles in each drift. Based on the amplitudes of both specimens, it can be seen that the amplitude of beam-column joint with GFRP is lower than the beam-column joint without GFRP. This suggests that the presence of GFRP reduces the intensity of the loading. This study also discusses the energy dissipation and equivalent viscous damping on both specimens. During the experiment, each crack, void between the concrete, and spalling of concrete fragments were carefully monitored. Visual observation during the experiment shows that severe cracking is evident on the inner part of the structure in both specimens. Therefore, a new location of GFRP-NSM would be suggested for a future experiment.
format Article
id my-ukm.journal.21120
institution Universiti Kebangsaan Malaysia
language en
publishDate 2022
publisher Penerbit Universiti Kebangsaan Malaysia
record_format eprints
spelling my-ukm.journal.211202023-02-14T10:02:36Z http://journalarticle.ukm.my/21120/ Seismic resistance evaluation of reinforced concrete (RC) exterior beam-column joints with and without GFRP under quasi-static lateral cyclic loading by adopting experimental analysis Mohd Razmi Mohd Amit, Asma Nabila Abd. Kader, M.Y.M Yatim, The beam-column joint is an important component of Reinforced Concrete (RC) structures because its design and detailing are critical to the safety of these structures under seismic loading. In recent decades, structural behaviour of beam-column joints has been widely explored. To better understand the behaviour of beam-column joints, researchers have conducted experiments and provided analytical and experimental solutions. The seismic behaviour of beam-column joints with and without Glass Fibre Reinforced Polymer (GFRP) when subjected to quasi-static lateral cyclic loading was compared in this research using two specimens. The first specimen is a typical RC exterior beam-column joint without GFRP while the second specimen is RC exterior beam-column joint that is pre-installed with Glass Fibre Reinforced Polymer (GFRP) using Near-Surface Mounted (NSM) technique. The specimens were evaluated to a drift of 2.0% under quasi-static lateral cyclic loading. There were two cycles in each drift. Based on the amplitudes of both specimens, it can be seen that the amplitude of beam-column joint with GFRP is lower than the beam-column joint without GFRP. This suggests that the presence of GFRP reduces the intensity of the loading. This study also discusses the energy dissipation and equivalent viscous damping on both specimens. During the experiment, each crack, void between the concrete, and spalling of concrete fragments were carefully monitored. Visual observation during the experiment shows that severe cracking is evident on the inner part of the structure in both specimens. Therefore, a new location of GFRP-NSM would be suggested for a future experiment. Penerbit Universiti Kebangsaan Malaysia 2022 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/21120/1/Jk_17.pdf Mohd Razmi Mohd Amit, and Asma Nabila Abd. Kader, and M.Y.M Yatim, (2022) Seismic resistance evaluation of reinforced concrete (RC) exterior beam-column joints with and without GFRP under quasi-static lateral cyclic loading by adopting experimental analysis. Jurnal Kejuruteraan, 34 (6). pp. 1175-1184. ISSN 0128-0198 https://www.ukm.my/jkukm/volume-3406-2022/
spellingShingle Mohd Razmi Mohd Amit,
Asma Nabila Abd. Kader,
M.Y.M Yatim,
Seismic resistance evaluation of reinforced concrete (RC) exterior beam-column joints with and without GFRP under quasi-static lateral cyclic loading by adopting experimental analysis
title Seismic resistance evaluation of reinforced concrete (RC) exterior beam-column joints with and without GFRP under quasi-static lateral cyclic loading by adopting experimental analysis
title_full Seismic resistance evaluation of reinforced concrete (RC) exterior beam-column joints with and without GFRP under quasi-static lateral cyclic loading by adopting experimental analysis
title_fullStr Seismic resistance evaluation of reinforced concrete (RC) exterior beam-column joints with and without GFRP under quasi-static lateral cyclic loading by adopting experimental analysis
title_full_unstemmed Seismic resistance evaluation of reinforced concrete (RC) exterior beam-column joints with and without GFRP under quasi-static lateral cyclic loading by adopting experimental analysis
title_short Seismic resistance evaluation of reinforced concrete (RC) exterior beam-column joints with and without GFRP under quasi-static lateral cyclic loading by adopting experimental analysis
title_sort seismic resistance evaluation of reinforced concrete (rc) exterior beam-column joints with and without gfrp under quasi-static lateral cyclic loading by adopting experimental analysis
url http://journalarticle.ukm.my/21120/1/Jk_17.pdf
http://journalarticle.ukm.my/21120/
https://www.ukm.my/jkukm/volume-3406-2022/
url_provider http://journalarticle.ukm.my/