Tube-Cornea Touch Following an Ahmed Valve Implantation in a Patient with Congenital Rubella Syndrome: A Case Report.

This was a 28-year-old mentally-challenged girl with underlying congenital Rubella syndrome. She was bilaterally aphakic after congenital cataract surgery. She then developed bilateral aphakic glaucoma and had to undergo multiple glaucoma filtering surgeries. The most recent procedure she had underg...

Full description

Saved in:
Bibliographic Details
Main Authors: Ooi, Edwin IL, Safinaz MK, Ropilah AR
Format: Article
Language:en
Published: Department of Surgery, UKM Medical Centre 2014
Online Access:http://journalarticle.ukm.my/8356/1/15-MS1176_%2853-55%29_ok.pdf
http://journalarticle.ukm.my/8356/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1831356452026974208
author Ooi, Edwin IL
Safinaz MK,
Ropilah AR,
author_facet Ooi, Edwin IL
Safinaz MK,
Ropilah AR,
author_sort Ooi, Edwin IL
building Tun Sri Lanang Library
collection Institutional Repository
content_provider Universiti Kebangsaan Malaysia
content_source UKM Journal Article Repository
continent Asia
country Malaysia
description This was a 28-year-old mentally-challenged girl with underlying congenital Rubella syndrome. She was bilaterally aphakic after congenital cataract surgery. She then developed bilateral aphakic glaucoma and had to undergo multiple glaucoma filtering surgeries. The most recent procedure she had undergone for her left eye was a second Ahmed valve implantation with an overlying sclera patch. Postoperatively, intraocular pressure was well controlled. However, nine months later, slit lamp examination revealed the tube was adherent to the overlying cornea with surrounding deep and superficial cornea vascularization. Siedel test was negative and intraocular pressure was normal. Subsequently the tube was removed but the plate was left in situ.
format Article
id my-ukm.journal-8356
institution Universiti Kebangsaan Malaysia
language en
publishDate 2014
publisher Department of Surgery, UKM Medical Centre
record_format eprints
spelling my-ukm.journal-83562016-12-14T06:47:01Z http://journalarticle.ukm.my/8356/ Tube-Cornea Touch Following an Ahmed Valve Implantation in a Patient with Congenital Rubella Syndrome: A Case Report. Ooi, Edwin IL Safinaz MK, Ropilah AR, This was a 28-year-old mentally-challenged girl with underlying congenital Rubella syndrome. She was bilaterally aphakic after congenital cataract surgery. She then developed bilateral aphakic glaucoma and had to undergo multiple glaucoma filtering surgeries. The most recent procedure she had undergone for her left eye was a second Ahmed valve implantation with an overlying sclera patch. Postoperatively, intraocular pressure was well controlled. However, nine months later, slit lamp examination revealed the tube was adherent to the overlying cornea with surrounding deep and superficial cornea vascularization. Siedel test was negative and intraocular pressure was normal. Subsequently the tube was removed but the plate was left in situ. Department of Surgery, UKM Medical Centre 2014-06-01 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/8356/1/15-MS1176_%2853-55%29_ok.pdf Ooi, Edwin IL and Safinaz MK, and Ropilah AR, (2014) Tube-Cornea Touch Following an Ahmed Valve Implantation in a Patient with Congenital Rubella Syndrome: A Case Report. Journal of Surgical Academia, 4 (2). pp. 53-55. ISSN 2231-7481
spellingShingle Ooi, Edwin IL
Safinaz MK,
Ropilah AR,
Tube-Cornea Touch Following an Ahmed Valve Implantation in a Patient with Congenital Rubella Syndrome: A Case Report.
title Tube-Cornea Touch Following an Ahmed Valve Implantation in a Patient with Congenital Rubella Syndrome: A Case Report.
title_full Tube-Cornea Touch Following an Ahmed Valve Implantation in a Patient with Congenital Rubella Syndrome: A Case Report.
title_fullStr Tube-Cornea Touch Following an Ahmed Valve Implantation in a Patient with Congenital Rubella Syndrome: A Case Report.
title_full_unstemmed Tube-Cornea Touch Following an Ahmed Valve Implantation in a Patient with Congenital Rubella Syndrome: A Case Report.
title_short Tube-Cornea Touch Following an Ahmed Valve Implantation in a Patient with Congenital Rubella Syndrome: A Case Report.
title_sort tube-cornea touch following an ahmed valve implantation in a patient with congenital rubella syndrome: a case report.
url http://journalarticle.ukm.my/8356/1/15-MS1176_%2853-55%29_ok.pdf
http://journalarticle.ukm.my/8356/
url_provider http://journalarticle.ukm.my/