Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV

The objective of this study was to develop a method for the determination of diuron (3-(3,4-dichlorophenyl)-1,1-dimethyl urea) residue in crude palm oil (CPO) and crude palm kernel oil (CPKO) matrices. The method involves the extraction of the herbicide from the oil matrix using low temperature prec...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd. Izwarie Ramli, Zuriati Zakaria, Ismail Sahid, Tan, Yew Ai, Halimah Muhamad
Format: Article
Language:en
Published: Universiti Kebangsaan Malaysia 2012
Online Access:http://journalarticle.ukm.my/5582/1/15%2520Mohd%2520Izwarie%2520.pdf
http://journalarticle.ukm.my/5582/
http://www.ukm.my/jsm/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1831355547590328320
author Mohd. Izwarie Ramli,
Zuriati Zakaria,
Ismail Sahid,
Tan, Yew Ai
Halimah Muhamad,
author_facet Mohd. Izwarie Ramli,
Zuriati Zakaria,
Ismail Sahid,
Tan, Yew Ai
Halimah Muhamad,
author_sort Mohd. Izwarie Ramli,
building Tun Sri Lanang Library
collection Institutional Repository
content_provider Universiti Kebangsaan Malaysia
content_source UKM Journal Article Repository
continent Asia
country Malaysia
description The objective of this study was to develop a method for the determination of diuron (3-(3,4-dichlorophenyl)-1,1-dimethyl urea) residue in crude palm oil (CPO) and crude palm kernel oil (CPKO) matrices. The method involves the extraction of the herbicide from the oil matrix using low temperature precipitation and solid phase extraction techniques, detected by high performance liquid chromatography-ultra violet (HPLC-UV). The HPLC separation was carried out on an AscentisTM RP-Amide column and elution with acetonitrile (solvent A) and water-methanol (2:1, v/v) (solvent B) as a suitable solvent system, at ratio of 4:6 (v/v). The optimum volume of acetonitrile for the extraction of diuron was 30 mL and 4 mL was obtained as the optimum volume of the solvent for elution analyte through the SPE cartridge. A linear correlation was obtained for the concentration of diuron from 0.05–1.0 μg mL-1 with a correlation coefficient of 0.99. The recovery of diuron from CPO was 83.2–101.4% with a relative standard deviation of 1.4–9.9% and 79.4–87.9% with relative standard deviation of 0.9–5.6% for CPKO. The method detection limit and limit of quantification obtained were 0.018 μg g-1 and 0.058 μg g-1, respectively. The method was used to determine diuron residues in palm oil from different refineries situated at different locations throughout Malaysia
format Article
id my-ukm.journal-5582
institution Universiti Kebangsaan Malaysia
language en
publishDate 2012
publisher Universiti Kebangsaan Malaysia
record_format eprints
spelling my-ukm.journal-55822016-12-14T06:38:53Z http://journalarticle.ukm.my/5582/ Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV Mohd. Izwarie Ramli, Zuriati Zakaria, Ismail Sahid, Tan, Yew Ai Halimah Muhamad, The objective of this study was to develop a method for the determination of diuron (3-(3,4-dichlorophenyl)-1,1-dimethyl urea) residue in crude palm oil (CPO) and crude palm kernel oil (CPKO) matrices. The method involves the extraction of the herbicide from the oil matrix using low temperature precipitation and solid phase extraction techniques, detected by high performance liquid chromatography-ultra violet (HPLC-UV). The HPLC separation was carried out on an AscentisTM RP-Amide column and elution with acetonitrile (solvent A) and water-methanol (2:1, v/v) (solvent B) as a suitable solvent system, at ratio of 4:6 (v/v). The optimum volume of acetonitrile for the extraction of diuron was 30 mL and 4 mL was obtained as the optimum volume of the solvent for elution analyte through the SPE cartridge. A linear correlation was obtained for the concentration of diuron from 0.05–1.0 μg mL-1 with a correlation coefficient of 0.99. The recovery of diuron from CPO was 83.2–101.4% with a relative standard deviation of 1.4–9.9% and 79.4–87.9% with relative standard deviation of 0.9–5.6% for CPKO. The method detection limit and limit of quantification obtained were 0.018 μg g-1 and 0.058 μg g-1, respectively. The method was used to determine diuron residues in palm oil from different refineries situated at different locations throughout Malaysia Universiti Kebangsaan Malaysia 2012-11 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/5582/1/15%2520Mohd%2520Izwarie%2520.pdf Mohd. Izwarie Ramli, and Zuriati Zakaria, and Ismail Sahid, and Tan, Yew Ai and Halimah Muhamad, (2012) Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV. Sains Malaysiana, 41 (11). pp. 1451-1459. ISSN 0126-6039 http://www.ukm.my/jsm/
spellingShingle Mohd. Izwarie Ramli,
Zuriati Zakaria,
Ismail Sahid,
Tan, Yew Ai
Halimah Muhamad,
Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV
title Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV
title_full Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV
title_fullStr Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV
title_full_unstemmed Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV
title_short Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV
title_sort determination of herbicide diuron levels in palm oil matrices using hplc-uv
url http://journalarticle.ukm.my/5582/1/15%2520Mohd%2520Izwarie%2520.pdf
http://journalarticle.ukm.my/5582/
http://www.ukm.my/jsm/
url_provider http://journalarticle.ukm.my/