Fitted curve paramaters for the efficiency of a coaxial HPGe detector
Using Ngraph software, the parameters of various functions were determined by least squares analysis of fits to experimental efficiencies, εf of a coaxial HPGe detector for gamma rays in the energy range 59 keV to 1836 keV. When these parameters had been determined, their reliability was tested by...
Saved in:
| Main Author: | |
|---|---|
| Format: | Article |
| Published: |
Universiti Kebangsaan Malaysia
1996
|
| Online Access: | http://journalarticle.ukm.my/3690/ http://www.ukm.my/jsm/english_journals/vol25num2_1996/vol25num2_96page27-34.html |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1831354944098140160 |
|---|---|
| author | Supian Samat, |
| author_facet | Supian Samat, |
| author_sort | Supian Samat, |
| building | Tun Sri Lanang Library |
| collection | Institutional Repository |
| content_provider | Universiti Kebangsaan Malaysia |
| content_source | UKM Journal Article Repository |
| continent | Asia |
| country | Malaysia |
| description | Using Ngraph software, the parameters of various functions were determined by least squares analysis of fits to experimental efficiencies, εf of a coaxial HPGe detector for gamma rays in the energy range 59 keV to 1836 keV. When these parameters had been determined, their reliability was tested by the calculated goodness-of-fit parameter χ2cal It is shown that the function, where n = 3, gives satisfactory results. |
| format | Article |
| id | my-ukm.journal-3690 |
| institution | Universiti Kebangsaan Malaysia |
| publishDate | 1996 |
| publisher | Universiti Kebangsaan Malaysia |
| record_format | eprints |
| spelling | my-ukm.journal-36902012-04-30T06:50:34Z http://journalarticle.ukm.my/3690/ Fitted curve paramaters for the efficiency of a coaxial HPGe detector Supian Samat, Using Ngraph software, the parameters of various functions were determined by least squares analysis of fits to experimental efficiencies, εf of a coaxial HPGe detector for gamma rays in the energy range 59 keV to 1836 keV. When these parameters had been determined, their reliability was tested by the calculated goodness-of-fit parameter χ2cal It is shown that the function, where n = 3, gives satisfactory results. Universiti Kebangsaan Malaysia 1996-06 Article PeerReviewed Supian Samat, (1996) Fitted curve paramaters for the efficiency of a coaxial HPGe detector. Sains Malaysiana, 25 (2). pp. 27-34. ISSN 0126-6039 http://www.ukm.my/jsm/english_journals/vol25num2_1996/vol25num2_96page27-34.html |
| spellingShingle | Supian Samat, Fitted curve paramaters for the efficiency of a coaxial HPGe detector |
| title | Fitted curve paramaters for the efficiency of a coaxial HPGe detector |
| title_full | Fitted curve paramaters for the efficiency of a coaxial HPGe detector |
| title_fullStr | Fitted curve paramaters for the efficiency of a coaxial HPGe detector |
| title_full_unstemmed | Fitted curve paramaters for the efficiency of a coaxial HPGe detector |
| title_short | Fitted curve paramaters for the efficiency of a coaxial HPGe detector |
| title_sort | fitted curve paramaters for the efficiency of a coaxial hpge detector |
| url | http://journalarticle.ukm.my/3690/ http://www.ukm.my/jsm/english_journals/vol25num2_1996/vol25num2_96page27-34.html |
| url_provider | http://journalarticle.ukm.my/ |