Removal of aluminium from drinking water

Aluminium in drinking water comes from natural sources and the alum used as coagulant in the water treatment process. Exposure to aluminium has been implicated in dialysis dementia, Parkinson and Alzheimer’s disease. Drinking water containing aluminium was considered to be one of the main sources of...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohamad Nasir Othman, Md. Pauzi Abdullah, Yang Farina Abd. Aziz
Format: Article
Language:en
Published: Penerbit Universiti Kebangsaan Malaysia 2010
Online Access:http://journalarticle.ukm.my/323/3/07.pdf
http://journalarticle.ukm.my/323/
https://www.ukm.my/jsm/malay_journals/jilid39bil1_2010/KandunganJilid39Bil1_2010.html
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1831352946148769792
author Mohamad Nasir Othman,
Md. Pauzi Abdullah,
Yang Farina Abd. Aziz,
author_facet Mohamad Nasir Othman,
Md. Pauzi Abdullah,
Yang Farina Abd. Aziz,
author_sort Mohamad Nasir Othman,
building Tun Sri Lanang Library
collection Institutional Repository
content_provider Universiti Kebangsaan Malaysia
content_source UKM Journal Article Repository
continent Asia
country Malaysia
description Aluminium in drinking water comes from natural sources and the alum used as coagulant in the water treatment process. Exposure to aluminium has been implicated in dialysis dementia, Parkinson and Alzheimer’s disease. Drinking water containing aluminium was considered to be one of the main sources of Al intake into human body. For this reason, the removal of aluminium from drinking water is vital to our health. In this study, removal of aluminium was carried out by using a chelating resin. To achieve the purpose, two chelating resin iontosorb oxin (IO) and polyhydroxamic acid (PHA) were used. The effects of concentration, pH, stirring time and resin amount was investigated. The concentration range varied between 10 and 500 ppb, pH range was between 2 and 12, stirring time between 5 and 60 minutes, and resin amount between 100 and 1500 mg. The optimum conditions of these resins were determined in a batch system. The results obtained showed that the optimum condition to remove aluminium for polyhydroxamic acid and iontosorb was pH 5-8 and pH 4-9; concentration range between 50-500 ppb, and 150-500 ppb, resin amount 200 mg and the stirring time was 20 minutes, respectively.
format Article
id my-ukm.journal-323
institution Universiti Kebangsaan Malaysia
language en
publishDate 2010
publisher Penerbit Universiti Kebangsaan Malaysia
record_format eprints
spelling my-ukm.journal-3232022-07-27T07:44:40Z http://journalarticle.ukm.my/323/ Removal of aluminium from drinking water Mohamad Nasir Othman, Md. Pauzi Abdullah, Yang Farina Abd. Aziz, Aluminium in drinking water comes from natural sources and the alum used as coagulant in the water treatment process. Exposure to aluminium has been implicated in dialysis dementia, Parkinson and Alzheimer’s disease. Drinking water containing aluminium was considered to be one of the main sources of Al intake into human body. For this reason, the removal of aluminium from drinking water is vital to our health. In this study, removal of aluminium was carried out by using a chelating resin. To achieve the purpose, two chelating resin iontosorb oxin (IO) and polyhydroxamic acid (PHA) were used. The effects of concentration, pH, stirring time and resin amount was investigated. The concentration range varied between 10 and 500 ppb, pH range was between 2 and 12, stirring time between 5 and 60 minutes, and resin amount between 100 and 1500 mg. The optimum conditions of these resins were determined in a batch system. The results obtained showed that the optimum condition to remove aluminium for polyhydroxamic acid and iontosorb was pH 5-8 and pH 4-9; concentration range between 50-500 ppb, and 150-500 ppb, resin amount 200 mg and the stirring time was 20 minutes, respectively. Penerbit Universiti Kebangsaan Malaysia 2010-02 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/323/3/07.pdf Mohamad Nasir Othman, and Md. Pauzi Abdullah, and Yang Farina Abd. Aziz, (2010) Removal of aluminium from drinking water. Sains Malaysiana, 39 (1). pp. 51-56. ISSN 0126-6039 https://www.ukm.my/jsm/malay_journals/jilid39bil1_2010/KandunganJilid39Bil1_2010.html
spellingShingle Mohamad Nasir Othman,
Md. Pauzi Abdullah,
Yang Farina Abd. Aziz,
Removal of aluminium from drinking water
title Removal of aluminium from drinking water
title_full Removal of aluminium from drinking water
title_fullStr Removal of aluminium from drinking water
title_full_unstemmed Removal of aluminium from drinking water
title_short Removal of aluminium from drinking water
title_sort removal of aluminium from drinking water
url http://journalarticle.ukm.my/323/3/07.pdf
http://journalarticle.ukm.my/323/
https://www.ukm.my/jsm/malay_journals/jilid39bil1_2010/KandunganJilid39Bil1_2010.html
url_provider http://journalarticle.ukm.my/