Effect of different qualities of foam on fill particle transport in horizontal well cleanup operation using coiled tubing
This study focuses on the effect of foam quality on fill concentration during coil tubing cleanup operation. Thus, to quantify such effect, it is required to develop the numerical model to investigate the well cleaning. ANSYS CFX-14 is used for numerical study of fill transport in the horizontal wel...
保存先:
主要な著者: | Khan, J.A., Pao, W.K. |
---|---|
フォーマット: | 論文 |
出版事項: |
2014
|
オンライン・アクセス: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84896817434&doi=10.4028%2fwww.scientific.net%2fAMR.903.39&partnerID=40&md5=f470113502dc10730255993d58297a69 http://eprints.utp.edu.my/31322/ |
タグ: |
タグ追加
タグなし, このレコードへの初めてのタグを付けませんか!
|
類似資料
-
Horizontal Well Cleanup Operation using Foam in Different Coiled Tubing/Annulus Diameter Ratios
著者:: Khan, Javed, 等
出版事項: (2013) -
Fill Removal with Foam in Horizontal Well Cleaning in Coiled Tubing
著者:: Khan, Javed A, 等
出版事項: (2013) - Fill removal with foam in horizontal well cleaning in coiled tubing
-
Factors affecting fill removal from horizontal well during colied tubing cleanout operation
著者:: Pao, W.K., 等
出版事項: (2014) -
FILL REMOVAL FROM HORIZONTAL WELLBORE USING FOAM IN COILED
TUBING
著者:: KHAN, JAVED AKBAR
出版事項: (2013)