Investigation into low energy beta imaging using CCD imaging sensor
Autoradiography is an extensively used technique to create a record of the radioactivity dispersion throughout the biological samples. Conventionally, this technique was performed using film. Spatial resolution and sensitivity are the main parameters of interest in developing new digital autoradiogr...
Saved in:
主要作者: | |
---|---|
格式: | Thesis |
语言: | English |
出版: |
2004
|
主题: | |
在线阅读: | http://eprints.utm.my/id/eprint/6840/1/SuhairulHashimMFS2004.pdf http://eprints.utm.my/id/eprint/6840/ http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:62447 |
标签: |
添加标签
没有标签, 成为第一个标记此记录!
|
id |
my.utm.6840 |
---|---|
record_format |
eprints |
spelling |
my.utm.68402018-09-19T05:07:06Z http://eprints.utm.my/id/eprint/6840/ Investigation into low energy beta imaging using CCD imaging sensor Hashim, Suhairul QC Physics Autoradiography is an extensively used technique to create a record of the radioactivity dispersion throughout the biological samples. Conventionally, this technique was performed using film. Spatial resolution and sensitivity are the main parameters of interest in developing new digital autoradiography systems. In conventional autoradiography, the images that have been documented display an excellent spatial resolution but at the same time show lack of sensitivity, very limited dynamic range and non-linear response. To overcome the disadvantages of this method, digital autoradiography systems have been developed to address the major drawbacks of the former technique. 2004-09 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/6840/1/SuhairulHashimMFS2004.pdf Hashim, Suhairul (2004) Investigation into low energy beta imaging using CCD imaging sensor. Masters thesis, University of Surrey, United Kingdom, School of Electronics and Physical Sciences. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:62447 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
QC Physics |
spellingShingle |
QC Physics Hashim, Suhairul Investigation into low energy beta imaging using CCD imaging sensor |
description |
Autoradiography is an extensively used technique to create a record of the radioactivity dispersion throughout the biological samples. Conventionally, this technique was performed using film. Spatial resolution and sensitivity are the main parameters of interest in developing new digital autoradiography systems. In conventional autoradiography, the images that have been documented display an excellent spatial resolution but at the same time show lack of sensitivity, very limited dynamic range and non-linear response. To overcome the disadvantages of this method, digital autoradiography systems have been developed to address the major drawbacks of the former technique. |
format |
Thesis |
author |
Hashim, Suhairul |
author_facet |
Hashim, Suhairul |
author_sort |
Hashim, Suhairul |
title |
Investigation into low energy beta imaging using CCD imaging sensor |
title_short |
Investigation into low energy beta imaging using CCD imaging sensor |
title_full |
Investigation into low energy beta imaging using CCD imaging sensor |
title_fullStr |
Investigation into low energy beta imaging using CCD imaging sensor |
title_full_unstemmed |
Investigation into low energy beta imaging using CCD imaging sensor |
title_sort |
investigation into low energy beta imaging using ccd imaging sensor |
publishDate |
2004 |
url |
http://eprints.utm.my/id/eprint/6840/1/SuhairulHashimMFS2004.pdf http://eprints.utm.my/id/eprint/6840/ http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:62447 |
_version_ |
1643644652844220416 |
score |
13.251813 |