The effect of contact angle on triangular shape interrupted microchannel heat sinks performance

The effect of different contact angle on triangular shaped interrupted microchannel performance was studied by simulation using FLUENT software. The investigated effects were pressure drop and platinum film temperature. The flow in microchannel is laminar and single phase. Water was used as the wor...