Performance of solar photocatalysis and photo-fenton degradation of palm oil mill effluent [Prestasi fotopemangkinan dan degradasi foto-fenton menggunakan sinar suria ke atas efluen kilang minyak kelapa sawit]

Palm oil mill effluent (POME) contains significant amounts of organic matter, solids, and grease or oil, which requires appropriate treatment prior to being discharged into the environment. In this study, solar radiation was investigated as a possible source of photon in the solar TiO2 and ZnO photo...

全面介紹

Saved in:
書目詳細資料
Main Authors: Devagi, Kanakaraju, Nurul Liyana, Ahmad, Noorfaezah, Mohd Sedik, Long, Sylvester Gan Hsien, Tay Meng, Guan, Lim, Ying-Chin
格式: Article
語言:English
出版: The Malaysian Analytical Sciences Society 2017
主題:
在線閱讀:http://ir.unimas.my/id/eprint/18940/2/PERFORMANCE%20OF%20SOLAR%20-%20Copy.pdf
http://ir.unimas.my/id/eprint/18940/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85032009886&doi=10.17576%2fmjas-2017-2105-01&partnerID=40&md5=b1c6ccf04061d36208eab523dbf03559
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
id my.unimas.ir.18940
record_format eprints
spelling my.unimas.ir.189402022-06-08T08:44:56Z http://ir.unimas.my/id/eprint/18940/ Performance of solar photocatalysis and photo-fenton degradation of palm oil mill effluent [Prestasi fotopemangkinan dan degradasi foto-fenton menggunakan sinar suria ke atas efluen kilang minyak kelapa sawit] Devagi, Kanakaraju Nurul Liyana, Ahmad Noorfaezah, Mohd Sedik Long, Sylvester Gan Hsien Tay Meng, Guan Lim, Ying-Chin QD Chemistry Palm oil mill effluent (POME) contains significant amounts of organic matter, solids, and grease or oil, which requires appropriate treatment prior to being discharged into the environment. In this study, solar radiation was investigated as a possible source of photon in the solar TiO2 and ZnO photocatalysis, and solar photo-Fenton treatments to reduce the chemical oxygen demand (COD) in POME. The results indicated that solar photo-Fenton was more efficient in reducing COD levels compared to dark Fenton and indoor photo-Fenton. The highest removal was recorded at 89% in the presence of 1:30 ratio of Fe2+:H2O2 under acidic pH (~2.8) after 3 hours of solar exposure. Increased concentrations of H2O2 have greatly influenced the COD removal. Additionally, solar TiO2 photocatalysis (pH~3.7; TiO2 = 0.1 g/L) has outperformed solar photolysis and solar ZnO photocatalysis in reducing COD levels in POME. With successive increase of TiO2 from 0.02 to 0.1 g/L, the removal of COD had linearly increased from 54.3% to 88.5% after 5 hours of solar exposure. Based on the investigated conditions, the optimum TiO2 concentration of 0.1 g/L was concluded. In conclusion, solar TiO2 photocatalysis and solar photo-Fenton can be applied as possible means to reduce the organic loads in POME. © 2017, Malaysian Society of Analytical Sciences. All rights reserved. The Malaysian Analytical Sciences Society 2017-10 Article PeerReviewed text en http://ir.unimas.my/id/eprint/18940/2/PERFORMANCE%20OF%20SOLAR%20-%20Copy.pdf Devagi, Kanakaraju and Nurul Liyana, Ahmad and Noorfaezah, Mohd Sedik and Long, Sylvester Gan Hsien and Tay Meng, Guan and Lim, Ying-Chin (2017) Performance of solar photocatalysis and photo-fenton degradation of palm oil mill effluent [Prestasi fotopemangkinan dan degradasi foto-fenton menggunakan sinar suria ke atas efluen kilang minyak kelapa sawit]. Malaysian Journal of Analytical Sciences, 21 (5). pp. 996-1007. ISSN 1394-2506 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85032009886&doi=10.17576%2fmjas-2017-2105-01&partnerID=40&md5=b1c6ccf04061d36208eab523dbf03559 DOI: 10.17576/mjas-2017-2105-01
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
topic QD Chemistry
spellingShingle QD Chemistry
Devagi, Kanakaraju
Nurul Liyana, Ahmad
Noorfaezah, Mohd Sedik
Long, Sylvester Gan Hsien
Tay Meng, Guan
Lim, Ying-Chin
Performance of solar photocatalysis and photo-fenton degradation of palm oil mill effluent [Prestasi fotopemangkinan dan degradasi foto-fenton menggunakan sinar suria ke atas efluen kilang minyak kelapa sawit]
description Palm oil mill effluent (POME) contains significant amounts of organic matter, solids, and grease or oil, which requires appropriate treatment prior to being discharged into the environment. In this study, solar radiation was investigated as a possible source of photon in the solar TiO2 and ZnO photocatalysis, and solar photo-Fenton treatments to reduce the chemical oxygen demand (COD) in POME. The results indicated that solar photo-Fenton was more efficient in reducing COD levels compared to dark Fenton and indoor photo-Fenton. The highest removal was recorded at 89% in the presence of 1:30 ratio of Fe2+:H2O2 under acidic pH (~2.8) after 3 hours of solar exposure. Increased concentrations of H2O2 have greatly influenced the COD removal. Additionally, solar TiO2 photocatalysis (pH~3.7; TiO2 = 0.1 g/L) has outperformed solar photolysis and solar ZnO photocatalysis in reducing COD levels in POME. With successive increase of TiO2 from 0.02 to 0.1 g/L, the removal of COD had linearly increased from 54.3% to 88.5% after 5 hours of solar exposure. Based on the investigated conditions, the optimum TiO2 concentration of 0.1 g/L was concluded. In conclusion, solar TiO2 photocatalysis and solar photo-Fenton can be applied as possible means to reduce the organic loads in POME. © 2017, Malaysian Society of Analytical Sciences. All rights reserved.
format Article
author Devagi, Kanakaraju
Nurul Liyana, Ahmad
Noorfaezah, Mohd Sedik
Long, Sylvester Gan Hsien
Tay Meng, Guan
Lim, Ying-Chin
author_facet Devagi, Kanakaraju
Nurul Liyana, Ahmad
Noorfaezah, Mohd Sedik
Long, Sylvester Gan Hsien
Tay Meng, Guan
Lim, Ying-Chin
author_sort Devagi, Kanakaraju
title Performance of solar photocatalysis and photo-fenton degradation of palm oil mill effluent [Prestasi fotopemangkinan dan degradasi foto-fenton menggunakan sinar suria ke atas efluen kilang minyak kelapa sawit]
title_short Performance of solar photocatalysis and photo-fenton degradation of palm oil mill effluent [Prestasi fotopemangkinan dan degradasi foto-fenton menggunakan sinar suria ke atas efluen kilang minyak kelapa sawit]
title_full Performance of solar photocatalysis and photo-fenton degradation of palm oil mill effluent [Prestasi fotopemangkinan dan degradasi foto-fenton menggunakan sinar suria ke atas efluen kilang minyak kelapa sawit]
title_fullStr Performance of solar photocatalysis and photo-fenton degradation of palm oil mill effluent [Prestasi fotopemangkinan dan degradasi foto-fenton menggunakan sinar suria ke atas efluen kilang minyak kelapa sawit]
title_full_unstemmed Performance of solar photocatalysis and photo-fenton degradation of palm oil mill effluent [Prestasi fotopemangkinan dan degradasi foto-fenton menggunakan sinar suria ke atas efluen kilang minyak kelapa sawit]
title_sort performance of solar photocatalysis and photo-fenton degradation of palm oil mill effluent [prestasi fotopemangkinan dan degradasi foto-fenton menggunakan sinar suria ke atas efluen kilang minyak kelapa sawit]
publisher The Malaysian Analytical Sciences Society
publishDate 2017
url http://ir.unimas.my/id/eprint/18940/2/PERFORMANCE%20OF%20SOLAR%20-%20Copy.pdf
http://ir.unimas.my/id/eprint/18940/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85032009886&doi=10.17576%2fmjas-2017-2105-01&partnerID=40&md5=b1c6ccf04061d36208eab523dbf03559
_version_ 1735390521828835328
score 13.250246