Fault distance calculation considering sequence impedance values on the distribution network
Fault on distribution line needs to be stored as quickly as possible. It is due to fault effect to the damage of equipment and blackout. In this paper, single line to ground fault is considered in the simulation. The fault distance calculation is used an impedance-based method. The value of negative...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English |
Published: |
AIP Publishing
2023
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/41055/1/Fault%20Distance%20Calculation%20Considering%20Sequence%20Impedance%20Values%20on%20The%20Distribution%20Network%20-%20Abstract.pdf http://umpir.ump.edu.my/id/eprint/41055/2/Fault%20Distance%20Calculation%20Considering%20Sequence%20Impedance%20Values%20on%20The%20Distribution%20Network.pdf http://umpir.ump.edu.my/id/eprint/41055/ https://doi.org/10.1063/5.0135288 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.41055 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.410552024-04-26T06:49:01Z http://umpir.ump.edu.my/id/eprint/41055/ Fault distance calculation considering sequence impedance values on the distribution network J. Awalin, Lilik Syahirah, Abdul Halim Nor Azuana, Ramli QA Mathematics TK Electrical engineering. Electronics Nuclear engineering Fault on distribution line needs to be stored as quickly as possible. It is due to fault effect to the damage of equipment and blackout. In this paper, single line to ground fault is considered in the simulation. The fault distance calculation is used an impedance-based method. The value of negative and positive sequence impedance was utilized in the formulation. The various distances in each section are simulated in order to observe the accuracy of the impedance-based method. The test network was adopted from the real data from Tenaga Nasional Berhad (TNB) Malaysia. The network was installed as an underground distribution network with 19 nodes (branches and main feeder). The obtained result shows that by considering sequence impedance to the fault distance calculation, it is able to generate acceptable accuracy. AIP Publishing 2023 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/41055/1/Fault%20Distance%20Calculation%20Considering%20Sequence%20Impedance%20Values%20on%20The%20Distribution%20Network%20-%20Abstract.pdf pdf en http://umpir.ump.edu.my/id/eprint/41055/2/Fault%20Distance%20Calculation%20Considering%20Sequence%20Impedance%20Values%20on%20The%20Distribution%20Network.pdf J. Awalin, Lilik and Syahirah, Abdul Halim and Nor Azuana, Ramli (2023) Fault distance calculation considering sequence impedance values on the distribution network. In: AIP Conference Proceedings. International Conference on Advanced Technology and Multidiscipline (ICATAM) 2021 , 13 - 14 October 2021 , Surabaya, Indonesia. , 2536 (030015). ISSN 0094-243X ISBN 978-0-7354-4442-3 https://doi.org/10.1063/5.0135288 |
institution |
Universiti Malaysia Pahang Al-Sultan Abdullah |
building |
UMPSA Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang Al-Sultan Abdullah |
content_source |
UMPSA Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English English |
topic |
QA Mathematics TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
QA Mathematics TK Electrical engineering. Electronics Nuclear engineering J. Awalin, Lilik Syahirah, Abdul Halim Nor Azuana, Ramli Fault distance calculation considering sequence impedance values on the distribution network |
description |
Fault on distribution line needs to be stored as quickly as possible. It is due to fault effect to the damage of equipment and blackout. In this paper, single line to ground fault is considered in the simulation. The fault distance calculation is used an impedance-based method. The value of negative and positive sequence impedance was utilized in the formulation. The various distances in each section are simulated in order to observe the accuracy of the impedance-based method. The test network was adopted from the real data from Tenaga Nasional Berhad (TNB) Malaysia. The network was installed as an underground distribution network with 19 nodes (branches and main feeder). The obtained result shows that by considering sequence impedance to the fault distance calculation, it is able to generate acceptable accuracy. |
format |
Conference or Workshop Item |
author |
J. Awalin, Lilik Syahirah, Abdul Halim Nor Azuana, Ramli |
author_facet |
J. Awalin, Lilik Syahirah, Abdul Halim Nor Azuana, Ramli |
author_sort |
J. Awalin, Lilik |
title |
Fault distance calculation considering sequence impedance values on the distribution network |
title_short |
Fault distance calculation considering sequence impedance values on the distribution network |
title_full |
Fault distance calculation considering sequence impedance values on the distribution network |
title_fullStr |
Fault distance calculation considering sequence impedance values on the distribution network |
title_full_unstemmed |
Fault distance calculation considering sequence impedance values on the distribution network |
title_sort |
fault distance calculation considering sequence impedance values on the distribution network |
publisher |
AIP Publishing |
publishDate |
2023 |
url |
http://umpir.ump.edu.my/id/eprint/41055/1/Fault%20Distance%20Calculation%20Considering%20Sequence%20Impedance%20Values%20on%20The%20Distribution%20Network%20-%20Abstract.pdf http://umpir.ump.edu.my/id/eprint/41055/2/Fault%20Distance%20Calculation%20Considering%20Sequence%20Impedance%20Values%20on%20The%20Distribution%20Network.pdf http://umpir.ump.edu.my/id/eprint/41055/ https://doi.org/10.1063/5.0135288 |
_version_ |
1822924290559836160 |
score |
13.239859 |