The simultaneous determination of silicic, boric and carbonic acids in natural water via ion-exclusion chromatography with a charged aerosol detector

The simple and simultaneous determination of silicic, boric and carbonic acids was made using ion-exclusion chromatography (IEC) and a Corona™ charged aerosol detector (C-CAD). Silicic and boric acids were separated by the column packed with a weakly acidic cation-exchange resin in H+-form and ultra...

全面介紹

Saved in:
書目詳細資料
Main Authors: Otsuka, Yu, Nakatani, Nobutake, Takahashi, Takuya, Kozaki, Daisuke, Mori, Masanobu, Tanaka, Kazuhiko
格式: Article
語言:English
出版: MDPI 2016
主題:
在線閱讀:http://umpir.ump.edu.my/id/eprint/29878/1/The%20simultaneous%20determination%20of%20silicic%2C%20boric%20and%20carbonic.pdf
http://umpir.ump.edu.my/id/eprint/29878/
https://doi.org/10.3390/chromatography3010009
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
id my.ump.umpir.29878
record_format eprints
spelling my.ump.umpir.298782020-11-12T06:46:43Z http://umpir.ump.edu.my/id/eprint/29878/ The simultaneous determination of silicic, boric and carbonic acids in natural water via ion-exclusion chromatography with a charged aerosol detector Otsuka, Yu Nakatani, Nobutake Takahashi, Takuya Kozaki, Daisuke Mori, Masanobu Tanaka, Kazuhiko TP Chemical technology The simple and simultaneous determination of silicic, boric and carbonic acids was made using ion-exclusion chromatography (IEC) and a Corona™ charged aerosol detector (C-CAD). Silicic and boric acids were separated by the column packed with a weakly acidic cation-exchange resin in H+-form and ultra-pure water eluent, and the detector responses were improved by the addition of acetonitrile to eluent. Under the optimized conditions, the simultaneous determination of weak inorganic acids, except for carbonic acid, was successfully performed. When the conversion column packed with a strong acidic cation-exchange resin in Na+- or K+-form was inserted between the separation column and the detector, weak inorganic acids including carbonic acid could be detected by the C-CAD. The calibration curves were linear in the range of 0.5–10 mg·L−1 as Si for silicic acid (r2 = 0.996), 10–100 mg·L−1 as B for boric acid (r2 = 0.998) and 1.3–21 mg·L−1 as C for carbonic acid (r2 = 0.993). The detection limits based on three times the standard deviation were 0.03 mg·L−1 as Si for silicic acid, 0.40 mg·L−1 as B for boric acid and 0.08 mg·L−1 as C for carbonic acid. This method was applicable to river, hot spring and drinking water. MDPI 2016-03 Article PeerReviewed pdf en cc_by_4 http://umpir.ump.edu.my/id/eprint/29878/1/The%20simultaneous%20determination%20of%20silicic%2C%20boric%20and%20carbonic.pdf Otsuka, Yu and Nakatani, Nobutake and Takahashi, Takuya and Kozaki, Daisuke and Mori, Masanobu and Tanaka, Kazuhiko (2016) The simultaneous determination of silicic, boric and carbonic acids in natural water via ion-exclusion chromatography with a charged aerosol detector. Separations, 3 (1). pp. 1-10. ISSN 2297-8739. (Published) https://doi.org/10.3390/chromatography3010009
institution Universiti Malaysia Pahang Al-Sultan Abdullah
building UMPSA Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang Al-Sultan Abdullah
content_source UMPSA Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Otsuka, Yu
Nakatani, Nobutake
Takahashi, Takuya
Kozaki, Daisuke
Mori, Masanobu
Tanaka, Kazuhiko
The simultaneous determination of silicic, boric and carbonic acids in natural water via ion-exclusion chromatography with a charged aerosol detector
description The simple and simultaneous determination of silicic, boric and carbonic acids was made using ion-exclusion chromatography (IEC) and a Corona™ charged aerosol detector (C-CAD). Silicic and boric acids were separated by the column packed with a weakly acidic cation-exchange resin in H+-form and ultra-pure water eluent, and the detector responses were improved by the addition of acetonitrile to eluent. Under the optimized conditions, the simultaneous determination of weak inorganic acids, except for carbonic acid, was successfully performed. When the conversion column packed with a strong acidic cation-exchange resin in Na+- or K+-form was inserted between the separation column and the detector, weak inorganic acids including carbonic acid could be detected by the C-CAD. The calibration curves were linear in the range of 0.5–10 mg·L−1 as Si for silicic acid (r2 = 0.996), 10–100 mg·L−1 as B for boric acid (r2 = 0.998) and 1.3–21 mg·L−1 as C for carbonic acid (r2 = 0.993). The detection limits based on three times the standard deviation were 0.03 mg·L−1 as Si for silicic acid, 0.40 mg·L−1 as B for boric acid and 0.08 mg·L−1 as C for carbonic acid. This method was applicable to river, hot spring and drinking water.
format Article
author Otsuka, Yu
Nakatani, Nobutake
Takahashi, Takuya
Kozaki, Daisuke
Mori, Masanobu
Tanaka, Kazuhiko
author_facet Otsuka, Yu
Nakatani, Nobutake
Takahashi, Takuya
Kozaki, Daisuke
Mori, Masanobu
Tanaka, Kazuhiko
author_sort Otsuka, Yu
title The simultaneous determination of silicic, boric and carbonic acids in natural water via ion-exclusion chromatography with a charged aerosol detector
title_short The simultaneous determination of silicic, boric and carbonic acids in natural water via ion-exclusion chromatography with a charged aerosol detector
title_full The simultaneous determination of silicic, boric and carbonic acids in natural water via ion-exclusion chromatography with a charged aerosol detector
title_fullStr The simultaneous determination of silicic, boric and carbonic acids in natural water via ion-exclusion chromatography with a charged aerosol detector
title_full_unstemmed The simultaneous determination of silicic, boric and carbonic acids in natural water via ion-exclusion chromatography with a charged aerosol detector
title_sort simultaneous determination of silicic, boric and carbonic acids in natural water via ion-exclusion chromatography with a charged aerosol detector
publisher MDPI
publishDate 2016
url http://umpir.ump.edu.my/id/eprint/29878/1/The%20simultaneous%20determination%20of%20silicic%2C%20boric%20and%20carbonic.pdf
http://umpir.ump.edu.my/id/eprint/29878/
https://doi.org/10.3390/chromatography3010009
_version_ 1822921772047007744
score 13.251815