Internal energy analysis with nanofluids in header and riser tube of flat plate solar collector by CFD modelling

In this study, Computational Fluid Dynamics (CFD) modelling of internal energy with different nanofluids (TiO2 and crystal nano cellulose) studied. The modelling was three dimensional under Viscous Laminar model. The base fluid for nanoparticles was 60% water+40% ethylene glycol along with individua...

詳細記述

保存先:
書誌詳細
主要な著者: Farhana, K., Mahamude, A. S. F., K., Kadirgama, M. M., Rahman, M. M., Noor, D., Ramasamy
フォーマット: Conference or Workshop Item
言語:English
出版事項: IOP Publishing 2019
主題:
オンライン・アクセス:http://umpir.ump.edu.my/id/eprint/24130/1/Internal%20energy%20analysis%20with%20nanofluids%20in%20header.pdf
http://umpir.ump.edu.my/id/eprint/24130/
https://doi.org/10.1088/1757-899X/469/1/012069
タグ: タグ追加
タグなし, このレコードへの初めてのタグを付けませんか!
その他の書誌記述
要約:In this study, Computational Fluid Dynamics (CFD) modelling of internal energy with different nanofluids (TiO2 and crystal nano cellulose) studied. The modelling was three dimensional under Viscous Laminar model. The base fluid for nanoparticles was 60% water+40% ethylene glycol along with individual water and ethylene glycol fluids. Volume fraction of nanofluids was 0.5% and single-phase model used. The diameter of inlet and outlet was fixed of individual model and three kinds of designing model used here. The diameter of both header and riser tubes varied whereas the number of tubes varied only for riser. The results revealed that diameter and number of tubes (riser) do not affect on the internal energy. Since internal energy only depends on different properties of the inside fluids.