PNEUMATIC ARTIFICIAL MUSCLE CONSTRUCTION USING NATURAL FIBER "SILK" FOR BIO-MEDICAL ENGINEERING

The objective of this project is to design and develop a desirable low cost and lightweight Pneumatic Artificial Muscle PAM) actuator using different materials. In this work, the studies are conducted to find the effect of various braided materials such as nylon, steel and Natural Fiber (Silk). The...

詳細記述

保存先:
書誌詳細
第一著者: SUBRAMANIAM, KRISHNAN
フォーマット: 学位論文
言語:English
出版事項: 2012
オンライン・アクセス:http://utpedia.utp.edu.my/3316/1/KRISHNAN_AL_SUBRAMANIAM.pdf
http://utpedia.utp.edu.my/3316/
タグ: タグ追加
タグなし, このレコードへの初めてのタグを付けませんか!
id my-utp-utpedia.3316
record_format eprints
spelling my-utp-utpedia.33162017-01-25T09:41:09Z http://utpedia.utp.edu.my/3316/ PNEUMATIC ARTIFICIAL MUSCLE CONSTRUCTION USING NATURAL FIBER "SILK" FOR BIO-MEDICAL ENGINEERING SUBRAMANIAM, KRISHNAN The objective of this project is to design and develop a desirable low cost and lightweight Pneumatic Artificial Muscle PAM) actuator using different materials. In this work, the studies are conducted to find the effect of various braided materials such as nylon, steel and Natural Fiber (Silk). The analysis is carried out on actuators of having constant longitudinal length of 140 mm varying the diameter namely 15 mm, 20 mm and 30 mm. The experiment was set up to collect the length and force variation data of the artificial muscle with various compressed air pressures. The force generated by PAM purely depends on the rate of pressure added and removal from the actuator and is contractile in nature upon inflation. PAM actuators find wide applications in various facets of robotic equipments and industrial automation. They are easy to manufacture, low cost and can be integrated with human operations without any large scale safety requirements. The innovative idea of using silk as braided sleeves has many advantages: It is naturally available with higher stiffness and allowable tensile stress is higher than that of nylon and steel. At a low load actuation of 10 N, the 20 mm diameter the silicon(ny1on braided sleeve) actuator contracts 18.45 % , silicon(stee1 braided sleeve) actuator contracts 20 % and whereas silicon(si1k braided sleeve) actuator shows 17.90 % contraction at a inlet pressure of 3 bars. The movement of this actuator is soft which is similar to the human muscle; hence it is preferred for usage in bio medical applications 2012-03 Thesis NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/3316/1/KRISHNAN_AL_SUBRAMANIAM.pdf SUBRAMANIAM, KRISHNAN (2012) PNEUMATIC ARTIFICIAL MUSCLE CONSTRUCTION USING NATURAL FIBER "SILK" FOR BIO-MEDICAL ENGINEERING. Masters thesis, UNIVERSITI TEKNOLOGI PETRONAS.
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
description The objective of this project is to design and develop a desirable low cost and lightweight Pneumatic Artificial Muscle PAM) actuator using different materials. In this work, the studies are conducted to find the effect of various braided materials such as nylon, steel and Natural Fiber (Silk). The analysis is carried out on actuators of having constant longitudinal length of 140 mm varying the diameter namely 15 mm, 20 mm and 30 mm. The experiment was set up to collect the length and force variation data of the artificial muscle with various compressed air pressures. The force generated by PAM purely depends on the rate of pressure added and removal from the actuator and is contractile in nature upon inflation. PAM actuators find wide applications in various facets of robotic equipments and industrial automation. They are easy to manufacture, low cost and can be integrated with human operations without any large scale safety requirements. The innovative idea of using silk as braided sleeves has many advantages: It is naturally available with higher stiffness and allowable tensile stress is higher than that of nylon and steel. At a low load actuation of 10 N, the 20 mm diameter the silicon(ny1on braided sleeve) actuator contracts 18.45 % , silicon(stee1 braided sleeve) actuator contracts 20 % and whereas silicon(si1k braided sleeve) actuator shows 17.90 % contraction at a inlet pressure of 3 bars. The movement of this actuator is soft which is similar to the human muscle; hence it is preferred for usage in bio medical applications
format Thesis
author SUBRAMANIAM, KRISHNAN
spellingShingle SUBRAMANIAM, KRISHNAN
PNEUMATIC ARTIFICIAL MUSCLE CONSTRUCTION USING NATURAL FIBER "SILK" FOR BIO-MEDICAL ENGINEERING
author_facet SUBRAMANIAM, KRISHNAN
author_sort SUBRAMANIAM, KRISHNAN
title PNEUMATIC ARTIFICIAL MUSCLE CONSTRUCTION USING NATURAL FIBER "SILK" FOR BIO-MEDICAL ENGINEERING
title_short PNEUMATIC ARTIFICIAL MUSCLE CONSTRUCTION USING NATURAL FIBER "SILK" FOR BIO-MEDICAL ENGINEERING
title_full PNEUMATIC ARTIFICIAL MUSCLE CONSTRUCTION USING NATURAL FIBER "SILK" FOR BIO-MEDICAL ENGINEERING
title_fullStr PNEUMATIC ARTIFICIAL MUSCLE CONSTRUCTION USING NATURAL FIBER "SILK" FOR BIO-MEDICAL ENGINEERING
title_full_unstemmed PNEUMATIC ARTIFICIAL MUSCLE CONSTRUCTION USING NATURAL FIBER "SILK" FOR BIO-MEDICAL ENGINEERING
title_sort pneumatic artificial muscle construction using natural fiber "silk" for bio-medical engineering
publishDate 2012
url http://utpedia.utp.edu.my/3316/1/KRISHNAN_AL_SUBRAMANIAM.pdf
http://utpedia.utp.edu.my/3316/
_version_ 1739831026972098560
score 13.251813